        This study was carried out to examine the concentration and distribution characteristics of total airborne bacteria (TAB) and airborne mold in non-regulated public-use facilities. The arithmetic mean (AM) of the TAB in all facilities was 356.5 ± 419.3 CFU/m3, and the geometric means (GM) was 157.8 CFU/m3, which did not exceed the standard value of 800 CFU/m3. The highest concentration was 637.3 ± 372.0 CFU/m3 (GM: 534.9 CFU/m3) in the underground shopping mall. The AM of airborne mold in all facilities was 448.2 ± 429.6 CFU/m3 (GM: 285.4 CFU/m3), which did not exceed the standard value of 500 CFU/m3, but was close to it. In particular, subway station (AM: 661.5 ± 441.2 CFU/m3, GM: 540.0 CFU/ m3), large-scale store (AM: 587.6 ± 683.2 CFU/m3, GM: 297.8 CFU/m3), and private educational institute (AM: 528.8 ± 379.6 CFU/m3, GM: 373.7 CFU/m3) exceeded the standard. Operational taxonomic unit of 16S rDNA and ITS2 rDNA region was analyzed to profile bacteria and mold component in the air of the public-use facilities. As a result, Pseudomonas and Morganella are the major bacterial groups. Regarding mold, Aspergillus, Candida, Malassezia, and Penicillium are the major groups. Component of each airborne bacterial and mold groups varied depending on the type of public-use facilities.