검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out in order to evaluate the design suitability of gas scrubbers, which have been operated in Siheung and Ansan Smarthubs, as an odor removal device. Detailed design data of 31 gas scrubbers installed between 2005 to 2014 were investigated. All the scrubbers investigated were found to use a “packed bed” design, and 30 of them used pall rings as packing materials. In determining the bed diameter of scrubbers, many facilities used incorrect packing parameters, which resulted in inappropriate design values for the bed diameter. In determining of the height of packed bed, the height of transfer unit (HTU) was calculated incorrectly because of the misuse of both the constants of packing materials and Schmidt numbers. In addition, the values of number of transfer unit (NTU) were found to be underestimated due to the low removal efficiency goal. Therefore, the adapted values of packed bed height were quite different from the ones calculated in many facilities.
        4,000원