검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 11

        1.
        2024.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In this study, we report the microstructural evolution and shear strength of an Sn-Sb alloy, used for die attach process as a solder layer of backside metal (BSM). The Sb content in the binary system was less than 1 at%. A chip with the Sn-Sb BSM was attached to a Ag plated Cu lead frame. The microstructure evolution was investigated after die bonding at 330 °C, die bonding and isothermal heat treatment at 330 °C for 5 min and wire bonding at 260 °C, respectively. At the interface between the chip and lead frame, Ni3Sn4 and Ag3Sn intermetallic compounds (IMCs) layers and pure Sn regions were confirmed after die bonding. When the isothermal heat treatment is conducted, pure Sn regions disappear at the interface because the Sn is consumed to form Ni3Sn4 and Ag3Sn IMCs. After the wire bonding process, the interface is composed of Ni3Sn4, Ag3Sn and (Ag,Cu)3Sn IMCs. The Sn-Sb BSM had a high maximum shear strength of 78.2 MPa, which is higher than the required specification of 6.2 MPa. In addition, it showed good wetting flow.
        4,000원
        2.
        2021.02 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We report the effect of Standard Clean-1 (SC-1) cleaning to remove residual Ti layers after silicidation to prevent Al diffusion into Si wafer for Ti Schottky barrier diodes (Ti-SBD). Regardless of SC-1 cleaning, the presence of oxygen atoms is confirmed by Auger electron spectroscopy (AES) depth profile analysis between Al and Ti-silicide layers. Al atoms at the interface of Ti-silicide and Si wafer are detected, when the SC-1 cleaning is not conducted after rapid thermal annealing. On the other hand, Al atoms are not found at the interface of Ti-SBD after executing SC-1 cleaning. Al diffusion into the interface between Ti-silicide and Si wafer may be caused by thermal stress at the Ti-silicide layer. The difference of the thermal expansion coefficients of Ti and Ti-silicide gives rise to thermal stress at the interface during the Al layer deposition and sintering processes. Although a longer sintering time is conducted for Ti-SBD, the Al atoms do not diffuse into the surface of the Si wafer. Therefore, the removal of the Ti layer by the SC-1 cleaning can prevent Al diffusion for Ti-SBD.
        3,000원
        3.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out in order to evaluate the design suitability of gas scrubbers, which have been operated in Siheung and Ansan Smarthubs, as an odor removal device. Detailed design data of 31 gas scrubbers installed between 2005 to 2014 were investigated. All the scrubbers investigated were found to use a “packed bed” design, and 30 of them used pall rings as packing materials. In determining the bed diameter of scrubbers, many facilities used incorrect packing parameters, which resulted in inappropriate design values for the bed diameter. In determining of the height of packed bed, the height of transfer unit (HTU) was calculated incorrectly because of the misuse of both the constants of packing materials and Schmidt numbers. In addition, the values of number of transfer unit (NTU) were found to be underestimated due to the low removal efficiency goal. Therefore, the adapted values of packed bed height were quite different from the ones calculated in many facilities.
        4,000원
        4.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The emission concentrations of VOC and various odorous compounds were measured from different indoor process units located in 19 companies at the Ban Wall industrial complex from Jun. 2004 to Jan. 2005. The purpose of this study was to investigate the indoor pollution levels of various industrial facilities with respect to bothmalodorous compounds and volatile organic compounds (VOC). We also intended to build the database under the conditions affected by various anthropogenic processes with an aid of a statistical treatment. The three samplingmethods and five analytical techniques were applied tomeasure the sum of up to 32 individual compounds. According to this study, we were able to identify the importance ofmajormalodor compounds which include carbonyl compounds, reduced sulfur compounds, ammonia and trimethylamine. On the other hand, relative contribution of VOC as sources ofmalodor was ofminor significance except such compound as toluene. The overall results of this study thus indicate that the concentration levels of VOC in themanufacturing facilities are high enough to affect indoor laboring conditions.
        5,700원
        5.
        2006.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 악취민원이 빈발한 경기도 안산시에 위치한 반월공단의 주거지역과 공단지역 등을 중심으로 주요 관리대상으로 설정된 악취성분들에 대한 환경대기 중 농도분포 특성을 2년여 기간동안 6차례에 걸쳐 조사하였다. 이들의 거동을 이해하기 위해, 시간적(오전과 오후) 및 공간적(공단 내외부의 위치) 기준으로 분포특성에 대한 비교를 시도하였다. 그 결과, 오전시간대에 비해 오후시간대에 고농도 분포가 현저하게 높은 것으로 나타났다. 이와 유사하게 공간적인 기준으로 비교한 결과도 공단 내부에서 관측한 결과에서 대부분의 성분들이 고농도를 유지하는 것을 확인할 수 있었다. 본 연구의 결과는 안산시 주변 및 공단지역의 환경대기 중에 존재하는 악취성분들이 시간적 및 공간적 기준으로 다양한 분포특성을 취한다는 것을 보여주었다.
        4,300원
        6.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Odor emission characteristics of unit processes in 10 livestock farms and 3 manure treatment facilities in Kyonggi province were examined in terms of odorous compound concentration and dilution ratio values of the threshold limit measured by instrumental analysis and air dilution sensory test, respectively. The highest odor concentration was detected at the compositing process unit of each facility and the dilution ratio showed high correlation with the treatment capacity as well as hygiene of the facility. Odor intensities in some facilities showed severe fluctuations (10 to 27 times difference) in response to the wind speed and direction as well as other weather conditions. According to the instrumental analysis, the major odorous compounds in the research area appeared to be ammonia, hydrogen sulfide, trimethyl amine, acetaldehyde and carbonyl compounds. Although some facilities breed same livestock, the types of odorous compounds as well as their concentration profiles were dependent on the type of composting process and management skill. In addition, dilution ratio of the threshold limit did not always show positive correlation with the odorous compound concentrations, which indicates the necessity of applying both methodologies, sensory test, and instrumental analysis.
        4,000원
        7.
        2005.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대기환경 중에 존재하는 여러 가지 가스상 성분들을 채취 및 이송시키고자 할 때, 다양한 종류의 튜빙을 사용한다. 이와 같은 튜빙의 사용과 연계된 여러 가지 오차를 분석하기 위해, 악취황 성분들을 이용한 비교분석을 시도하였다. 이를 위해 45cm 길이로 6가지 재질의 튜빙을 선택하여, 각 튜빙별 손실특성을 평가하고자 하였다. 이를 위해, 10ppb 농도의 표준시료를 준비하고, 이를 튜빙에 통과시켜 준 후, 튜빙을 통과한 전후에 검출되는 농도를 비교하는 방식으로 손실율을 산출하였다. 이러한 비교의 목적상, 환원황 성분에 가장 우수한 회수율을 보이는 Silco Steel 튜빙을 통과한 결과를 기준 검량선으로 설정하고 여타 튜빙에 대한 회수율을 비교하였다. 그 결과 Teflon 튜빙에서는 4가지 황화합물 모두 90% 이상의 높은 회수율을 보일 정도로 양호한 결과를 보였다. 이에 비해 스테인레스나 브래스 재질의 경우, 저분자 황성분에 해당하는 H2S, CH3SH에서 상당한 손실을 보였다. 반면 실리콘 튜빙의 경우, 고분자 성분에 해당하는 DMS, DMDS에서 큰 손실을 보였다. 결과적으로 황화합물의 종류나 튜빙의 재질에 따라 RSC의 손실은 다양한 형태로 나타나는 것을 확인할 수 있다.
        4,000원
        10.
        2003.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 서울시에 의해 운영되는 서울시내 31개 지역의 대기오염 자동측정망에서 1990년부터 2000년까지 11년 동안 측정한 자료 중, TSP와 PM10에 대한 대기환경기준을 초과한 자료만을 선택적으로 분리한 후 여러 가지 통계적인 분석을 수행하였다. 이러한 연구목적에 맞추어, 각 토지 이용 상태별로 환경기준을 초과한 분진농도의 경향성을 비교해 본 결과, TSP의 경우 초과농도의 전반적인 발생분포가 녹지, 주거, 상업, 준공업지역 순서로 증가하는 양상을 보여주었다. 준공업 지역에서 351.0±35.9μg m3로 가장 높은 초과농도를 보였다. PM10의 초과농도는 주거지역에서 182.9±42.4μg m3의 최고농도를 보이며, 초과농도분포는 준공업, 상업, 녹지, 주거지역 순서로 증가하는 양상을 보인다. 발생빈도수를 각 지점별 측정망수로 나누어 준 결과 주거지역에서 21회로 다른지역에 비해 높은 초과빈도수를 보였다. 이들 초과농도자료들만에 국한시켜 시간적 주기성을 분석한 결과에 따르면, 일반적으로 관측되는 부유분진 자료들과 차별화 된 경향성이 어느 정도 확인되었다. 특히 계절적인 주기로 구분하였을 때, 일반농도자료는 PM10과 TSP 모두 겨울철에 가장 큰 농도를 보인데 반해, 초과농도는 다른 양상을 보여주었다. 이러한 연구결과, PM10의 연도별 경향성에서 가장 주목할 점은 측정이 시작된 1995년 이후 초과농도의 크기가 지속적으로 감소함에도 불구하고, 그 발생빈도수는 최근에 들어 괄목할 만큼 증가하고 있다는 점을 들 수 있다.
        4,800원
        11.
        2002.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 1990년부터 2000년까지 11년의 기간동안 서울지역 대기오염 자동측정망을 중심으로 관측된 오존자료 중 환경기준을 초과한 자료만을 선별적으로 분리한 후 분석에 활용하였다. 이와 같은 분석결과를 토대로 서울시의 4대 권역별 (NE, SE, SW, NW) 기준초과양상을 여러 가지 관점에서 비교해 보았다. 24시간을 주기로 초과농도의 발생 경향을 비교해 본 결과, SW지역이 다른 지역에 비해 오존의 총 발생시간이 더 많은 것을 확인할 수 있었다. 발생빈도를 중심으로 4대 지역에 대한 월별 경향성을 비교했을 때 NW지역에서 여타 지역보다 최고빈도의 발생시기가 약간 뒤처지는 현상이 나타났다. 해를 거듭할수록 오존의 환경기준 초과발생횟수가 증가하는 경향을 감지할 수 있다. 특히 이와 같은 현상은 NE, SE를 포함하는 서울의 동쪽지역에서 두드러지는 것으로 타나났다. 전체 11년동안 초과치의 최고 발생빈도를 지역별로 비교해 보면, NE지역에서 1998년에 그리고 나머지 세지역은 모두 2000년에 나타났다. 이처럼 오존의 환경기준 초과횟수는 최근에 들어 급격히 증가하는 것으로 확인되었다. 이에 반해, 초과농도의 크기에 대한 결과를 보면, 오히려 90년대 초반에 고농도가 집중된 데 반해, 90년대 후반에는 상대적으로 초과농도의 크기가 감소한 것으로 나타났다. 전체 관측기간동안 서울지역에서 관측된 평균 기온자료를 이용하여 오존초과자료와의 상관성을 분석하였다. 그 결과 대체로 크기나 빈도에 상관없이 모두 기온과 일정 수준 이상 양의 상관성을 유지하는 것이 확인되었다. 전반적으로 기온의 변화는 오존의 초과농도발생과 상당 수준 연계되었다는 점을 확인 할 수 있었다.완화시켜주는 효과도 있어 표준시를 안정적으로 운용하는 데에도 크게 기여하고 있는 것이다. 또한 이 I-시간은 UTC와 정수 시간차를 유지하면서 안정적으로 운영하려는 세계 각국의 표준시 운영 경향과도 잘 일치한다. 따라서 우리 나라가 태양시에 맞게 H*-시간을 사용해야 한다는 것은 태양시와 비슷한 표준시를 사용한다는 장점은 인정되지만, 그에 못지 않게 UTC와는 비 정수 시간차 시간을 운용하게 되며, 또한 하절기에는 서머타임을 도입해서라도 태양시보다 1시간 빠른 시간을 이용해야 한다는 필요성을 유발하게 된다는 점에서 결코 바람직하지 않다고 생각된다.혼합 처리 시에는 낮게 나타났다 이러한 실험 결과를 통하여 칼슘이 1.2 mM, 1.8 mM 농도로 존재하는 경우 카페인에 의한 골모세포의 염기성 인산분해효소 활성과 IL-1 β의 활성 억제 효과가 어느 정도 회복되나, 2.5 mM 고농도의 칼슘은 억제된 활성을 회복시키지 못함을 확인하였다.지 않고 다양한 분야 즉 디자인, 생활 속에서의 벽지문양과 포장지, 예술작품 등에 활용되고 있음을 체험함으로써 수학이 실생활에 광범위하게 활용되고 있음을 알게 하였다. 역으로 생활 속에서의 테셀레이션을 통해 수학적 개념을 찾는 과정을 통해 수학이 아름다우면서도 실용적이라는 생각을 심어줄 수 있었다. 셋째, 테셀매니아, GSP, 캐브리, 거북기하 등 평소 수업에서는 활용도가 적은 컴퓨터 소프트웨어를 활용함으로써 컴퓨터 소프트웨어 자체에서 오는 호기심뿐만이 아니라 직접 조작하여 테셀레이션 작품과 개념을 익히고 새로운 작품과 학습을 해 내는 과정을 통해 자신감과 성취감 등에 있어
        4,600원