        1.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was an attempt to analyze the basic analytical characteristics of octanal and nonanal compounds by TD and GC/FID system. The basic analysis (linearity, precision, MDL: method detection limit) showed similar results for VOCs in terms of QA/QC results with the same analysis system. Also, the results are sufficiently satisfy the QA/QC of the Korean odor analysis standard method. When using a polyester aluminum bag, the amount of loss was found to be about -2% to 7%. Adjusting the relative humidity and loss trend with the passage of time, the loss amount is found to be only a trace amount. With the exception of the styrene compound, all volatile organic compounds have a tendency to decrease slightly. Similar results were shown from Octanal and Nonanal. As a result, Octanal and Nonanal compound’s adsorption amount by the polyester aluminum bag was a quite small. The relative humidity and other compounds appear to be significantly unaffected by Octanal and Nonanal.
        4,500원
        2.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We studied an analytical method for 4 organic acids will be regulated in 2010 using on-line thermal desorber with gas chromatograph/flame ionization detector. Results for each compounds showed good linearity(r² > 0.99) and good precision(RSD < 3%). Minimum detection limit values are about 2~3ppb when we sampled 1.5 L. These values will be reduced to 0.4~0.5 ppb when sampling 10L. We analyzed the 56 ozone precursor standard gas using the same method to see if there are any peaks to be overlapped in ambient air and the results showed that there is no peak overlapped. The linearity, precision and MDL in this study satisfied the guideline of Korean standard method for 4 organic acids. This analytical method in this study could be utilized effectively as on-line monitoring instrument to detect 4 organic acids.
        4,000원
        3.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we attempt to analyze for 4 compounds (MEK, MIBK, n-Butyl acetate, i-Butyl alcohol) in ambient air using on-line thermal desorber (on-line TD) with gas chromatograph/flame ionization detector (GC/FID). These compounds will be regulated by KMOE (Korean ministry of environment) within 2010. We tested two different experimentation. First, we try to find the influence of Nafion dryer for the 4 compounds. Second, we want to know basic analytical characteristic of target compounds through the linearity, reproducibility, and minimum detection limit. According to this study, target compounds are removed in Nafion dryer more than 80 percent, respectively. So, we progressed next experimentation progressed without Nafion dryer using hydrophobic cold trap. Results for each compounds showed good linearity (r²=0.99 upper) and good precision (RSD=1 % below). In additional, we analyzed the ozone precusors standard gas (56 compounds) using the same method to see if there are any peaks to be overlapped in ambient air. These results showed that there is no peak overlapped. This means that analytical system of this study could be used on-line analytical system. Minimum detection limit (MDL) value for this system are less than minimum malodor threshold concentration.
        4,000원
        4.
        2007.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, QA/QC (quality control/quality assurance) data of reduced sulfur compounds from several institutes were obtained and compared based on the Korean standard method for off-odor. From the results, attempts were made to optimize the analytical conditions and improve the measurement reliability of reduced sulfur compounds analyses from detailed CF/TD and GC/PFPD information. Analysis results (minimum detection limit, precision, recovery rate) of reduced sulfur compounds based on the each analytical condition corresponded with the Korean standard methods for off-odor. Therefore, we expect that we could execute the exact analysis if we use the analytical condition of CF/TD and GC/PFPD in this study
        4,000원
        5.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The emission concentrations of VOC and various odorous compounds were measured from different indoor process units located in 19 companies at the Ban Wall industrial complex from Jun. 2004 to Jan. 2005. The purpose of this study was to investigate the indoor pollution levels of various industrial facilities with respect to bothmalodorous compounds and volatile organic compounds (VOC). We also intended to build the database under the conditions affected by various anthropogenic processes with an aid of a statistical treatment. The three samplingmethods and five analytical techniques were applied tomeasure the sum of up to 32 individual compounds. According to this study, we were able to identify the importance ofmajormalodor compounds which include carbonyl compounds, reduced sulfur compounds, ammonia and trimethylamine. On the other hand, relative contribution of VOC as sources ofmalodor was ofminor significance except such compound as toluene. The overall results of this study thus indicate that the concentration levels of VOC in themanufacturing facilities are high enough to affect indoor laboring conditions.
        5,700원
        6.
        1971.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        솔나방의 light-trap에 의한 유인력 비교와 시간별 유인효과, 유인되는 성간비교 및 유아등종의 개발과 trap형에 고나한 실험에서 다음과 같은 결과를 얻었다. 1. 솔나방의 인인성은 U.V. 파장 에서 가장 유인효과가 좋았다. 2. 솔나방의 유인 최성시각은 20:00-22:00시로서 그때의 유인수는 전체 유인수의 가 이 시각에 유인되었다. 3. 적색, 황색등에서는 유인효과를 볼수 없었다. 4. Blacklight-trap의 경우 20:00-22:00시까지 유인되는 성비는 로서 female의 유인수가 더 많았다. 5. 기상조건과 솔나방의 유인효과와는 상관관계가 없었다.