        Measurement of fluctuating pressure by tube system is carefully designed due to the organ-pipe resonance. It is necessary to correct the pressure before analysis. The three method for correction the distortion fluctuation pressure short tube length and the frequency response functions and insert a restrictor in the tube to increase the damping. The first method is useful when the tube length is short. In second method, the distorted signal through the tubing transformed into the frequency domain, dividing by transfer function and inverse fourier transforming back into the time domain gives the required pressure signal. In this paper three types of tubing which have different length of 100cm, 150cm, 200cm were experimented the distorted signal and correct the distortion signal