검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Lumbar stabilization (LS) improve the thickness of the quadratus lumborum (QL) muscle and muscle activity of the gluteus medius (GM) muscle during hip abduction in a side-lying position in patients with low back pain (LBP). Objects: The purpose of this study was to assess the effects of LS on muscle thickness of QL and muscle activity of GM during hip abduction in side-lying in patients with LBP. Methods: The study included 32 patients with LBP, who were randomly divided into the control group and experimental group, each with 16 patients. All subjects performed 35° preferred hip abduction (control group) and 35° hip abduction with LS (experimental group) during side-lying. An ultrasonography and a surface electromyography were used to measure the thickness of the QL muscle, and the muscle activities of the GM muscle respectively. Independent t-test was used to compare the muscle thickness of the QL and the muscle activity of the GM muscle, respectively. Results: Anterio-posterior diameter in the muscle thickness of QL muscle was decreased significantly in hip abduction with LS more than in preferred hip abduction (p<.001), but medio-lateral diameter in the muscle thickness of QL muscle was not significantly different between in preferred hip abduction and in hip abduction with LS (p=.06). The muscle activity of GM was increased significantly in hip abduction with LS more than in preferred hip abduction (p<.001). Conclusion: These findings suggest that hip abduction with LS could be recommended as a hip abduction for LS and a prevention unwanted compensatory pelvic lateral tilting movement.
        4,000원
        2.
        2015.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester’s hand over the subject’s clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B’s measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.
        4,000원