        2022.05 구독 인증기관·개인회원 무료
        Radioactively contaminated metal components from a nuclear power plant must be decontaminated to reduce the risk of radiation exposure to workers, which can be cleaned using a foam decontamination used to reduce the amount of wastewater significantly. Metal components with a fixed radioactive contamination can be effectively decontaminated using a foam consist of 0.5wt% nonionic surfactant, 0.5 M H2SO4, and 0.2 M Ce(SO4)2. However, strongly acidic wastewater is generated from the decontamination method, which contains a high concentration of the nonionic surfactant and ionic materials with radioactive nuclides. This wastewater must be treated as a stable form. In this study, an integrated process of precipitation and low pressure distillation was evaluated for the treatment of wastewater. It was confirmed that the surfactant and ionic materials were effectively removed from the wastewater through the integrated process.