검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2022.05 구독 인증기관·개인회원 무료
        Gamma-ray spectroscopy, which is an appropriate method to identify and quantify radionuclides, is widely utilized in radiological leakage monitoring of nuclear facilities, assay of radioactive wastes, and decontamination evaluation of post-processing such as decommissioning and remediation. For example, in the post-processing, it is conducted to verify the radioactivity level of the site before and after the work and decide to recycle or dispose the generated waste. For an accurate evaluation of gamma-ray emitting radionuclides, the measurement should be carried out near the region of interest on site, or a sample analysis should be performed in the laboratory. However, the region is inaccessible due to the safety-critical nature of nuclear facilities, and excessive radiation exposure to workers could be caused. In addition, in the case of subjects that may be contaminated inside such as pipe structures generated during decommissioning, surveying is usually done over the outside of them only, so the effectiveness of the result is limited. Thus, there is a need to develop a radiation measurement system that can be available in narrow space and can sense remotely with excellent performance. A liquid light guide (LLG), unlike typical optical fiber, is a light guide which has a liquid core. It has superior light transmissivity than any optical fiber and can be manufactured with a larger diameter. Additionally, it can deliver light with much greater intensity with very low attenuation along the length because there is no packing fraction and it has very high radiation resistant characteristics. Especially, thanks to the good transmissivity in UV-VIS wavelength, the LLG can well transmit the scintillation light signals from scintillators that have relatively short emission wavelengths, such as LaBr3:Ce and CeBr3. In this study, we developed a radiation sensor system based on a LLG for remote gamma-ray spectroscopy. We fabricated a radiation sensor with LaBr3:Ce scintillator and LLG, and acquired energy spectra of Cs-137 and Co-60 remotely. Furthermore, the results of gamma-ray spectroscopy using different lengths of LLG were compared with those obtained without LLG. Energy resolutions were estimated as 7.67%, 4.90%, and 4.81% at 662, 1,173, and 1,332 keV, respectively for 1 m long LLG, which shows similar values of a general NaI(Tl) scintillator. With 3 m long LLG, the energy resolutions were 7.92%, 5.48%, and 5.07% for 662, 1,173, and 1,332 keV gamma-rays, respectively.