검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the odor arising from the Cheong-ju industrial complex area for odor materials confirmation, and to predict the impact of the odor in the residential area using the CALPUFF Model. Among the odor causing substances in the area with a rising number of collective complaints due to odor, methyl sulfide, acetaldehyde, propionaldehyde, n-buthylaldehyde, n-valeraldehyde and styrene were detected. Odor causing substances detected in the area surrounding the industrial complex include ammonia, hydrogen sulfide, n-buthylaldehyde, toluene, xylene, benzene and styrene. Using the CALPUFF Model, it was predicted that 1hr average was 3.981~7.553 OU/m3 and 24hr average was 1.753~2.359 OU/m3. In terms of odor intensity, the predicted 1hr average was 0.6~0.9 and the 24hr average was 0.2~0.4.
        4,000원
        2.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        근래 국내 초고층 주상복합 건물에는 철근콘크리트구조가 보편적으로 적용되는데, 이러한 철근콘크리트 초고층 주상복합 건물은 시공 시점에 따라 구조적인 문제가 발생할 수 있다. 따라서, 시공 중인 철근콘크리트 초고층 주상복합 건물에 대하여, 시공 시점별 구조 안전성 및 횡력저항성능을 검토하고자 한다. 이를 위해, 예제 모델로 탑상형의 초고층 주상복합 60층 건물을 선정했고, 기존의 범용구조해석 프로그램을 사용하여 구조해석을 수행하였다. 각 시공 시점별 10층, 20층, 30층, 40층, 50층, 60층 완료모델과 60층 완공단계 모델의 구조성능을 비교하였다. 구조성능 비교를 위해 이 모델들의 고유치해석을 수행하였으며, 횡력저항성능과 부재별 단면성능을 검토하였다. 횡력저항성능 검토를 위해 횡변위비와 층간변위비를 검토했고, 부재별 단면성능 검토는 완공단계에 대한 설계강도비와 시공단계의 설계강도비를 비교하여 부재안전성을 검토하였다. 이 연구를 통해, 시공 중인 철근콘크리트 초고층 건물의 구조 안전성을 검토하고 시공단계에 적합한 구조해석 및 설계하중의 가이드라인을 제시하고자 한다.
        4,000원
        3.
        2007.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 초고층 주상복합건물의 품질관리를 통한 시공 분야의 효율성의 특성을 파악하는데 있다. 기존연구에서 시공관련 품질개선요소들이 정리되었으며 규격화된 설문서를 통하여 시공 분야에 있어서 개선요소를 대학원생을 포함한 건축 관련 대학교, 건설회사, 설계사무소등의 실무자들의 의견을 조합하였다. 설문조사 결과와 기존현장 기술자들의 품질관리 인식도를 비교하여 현장별 품질관리의 정량적, 정성적 성과척도를 파악하고 분석하였다.
        4,000원
        4.
        2012.06 KCI 등재 서비스 종료(열람 제한)
        This study aims to present the policy issues and direction of sub-urban residential complex by analyzing the settlement environment and life satisfaction. For the purpose, 10 sub-urban residential complexes in Chungnam Province were surveyed for general situation, physical environment, social environment, economic environment. The results are as follows; 1) The satisfaction in the physical environment is more higher in case of the complex created by the public organization. 2) The physical environment is an important factor in the determinant of the settlement, while the economic environment have a relatively lower impact. 3) The residents community is the more active, the satisfaction in the social environment is the more improved. 4) The source of income or the activity of consumption doesn't have an effect on the satisfaction in the economic environment. On the basis of this study, three programs for improvement of sub-urban residential complex policy were suggested. First, the various information and counseling service should be provided to attract city dwellers. Second, the policy on the development of sub-urban residential complex has to consider residential preference factors and improve the quality of life. Third, to increase the life satisfaction, the residents community should be activated and especially the activation of community with residents in other village is very important.
        5.
        2011.06 KCI 등재 서비스 종료(열람 제한)
        워터 프런트에 있어서의 집합주택은 전면에 퍼지는 수역의 경관을 얻을 수 있어 사람들의 생활에 윤택이나 안락함 등을 가져다 준다. 그러나 시가지와는 다른 워터프런트만의 환경적 이점을 살릴 계획 수법이 확립되어 있다고는 말하기 어려운 것이 현상이다. 본 연구에서는 일본의 워터프런트(니시노미야하마와 비와코) 거주자를 대상으로 앙케이트 조사를 실시하여 친수 활동, 거주 환경 의식과 거주 선택 이유 등에 대해 비교 분석을 실시하였다. 그 결과 향후의 워터 프런트에 입지하는 집합주택 거주자들의 거주환경에 대한 의식과 거주선택이유의 상이점을 알 수 있었다. 또 각각의 워터프런트지역에서 염해나 해충에 대한 대책 등 지역환경 특성에 맞는 문제점을 경감 대책의 필요성과 수변에의 전망을 확보를 희망하고 있으며 "방의 넓이" "통풍" "전망 채광" "프라이버시의 확보"등 워터프런트에 입지하는 집합주택의 계획수립 시에 상기한 거주환경의 조성이 거주자들의 주거의식에 영향을 미치고 있음을 알 수 있었다.
        6.
        2004.06 KCI 등재 서비스 종료(열람 제한)
        Air pollution from the Daegu industrial complex (DIC) in Korea has been a common nuisance and cause of complaints for nearby residents. The current study measured the indoor and outdoor levels of six VOC (benzene, toluene, ethylbenzene, and three isomeric xylenes) at two residential areas with a different proximity to the DDIC, plus the ambient levels at two industrial areas within the boundary of the DDIC. The QA/QC program included the range of correlation coefficient (0.94~0.99) for calibration curves, within the permissible range. Toluene was the most abundant VOC in the ambient air both in residential and industrial areas. Both indoor and outdoor air concentrations of all target VOC except benzene were higher in residential area near the DIC compared to that further away from the DIC. Moreover, the ambient air concentrations of all target VOC except benzene for two industrial sites (A and B) were significantly higher than the outdoor or indoor air concentrations in the two residential areas. The findings further suggested that VOC ambient levels measured in a residential area near the DIC be used as a potential indicator of odor-causing unidentified air pollutants transported from the DIC. Moreover, it was found that the elevated ambient toluene levels outweighed the indoor sources with respect to the environmental exposure of residents nearby the DIC. However, in the residential area further away from the DIC, the toluene indoor sources outweighed the outdoor sources.