        2.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Reverse osmosis seawater desalination facilities can extend the cleaning cycle and replacement time of the reverse osmosis membrane by pretreatment process. Selection of pretreatment process depends on water quality. It was attempted in this study to select approriate pretreatment process for the Masan bay, which was high in particles and organic content. For this purpose, performances of pretreatment processes such as filter adsorber (FA), pore controllable fiber (PCF), and ultrafiltration (UF) were compared based on the silt density index (SDI). The SDI value of the filtrate should be less than 3. The study results showed that UF can produce the filtrate quality satisfying the requirement. However, the transmembrane pressure (TMP) of UF increased quickly, reaching 0.6 bar within 4 days. In order to secure stable operation, FA and PCF were combined with UF. The study results showed that combination of PCF and UF was able to extend the filtration duration (more than 2 months) until to reach TMP of 0.6 bar.
        4,000원
        4.
        2018.11 구독 인증기관·개인회원 무료
        본 연구에서는 향후 역삼투식 해수담수화 기술의 에너지 효율을 개선하기 위한 3가지 방법을 제안한다. 그리고 제안된 방법이 적용되었을 때, 이론적인 최대 에너지 소모량 감소를 엑서지 분석을 통해 산출하고 현재 개발되고 있는 기술을 분석해서 실질적으로 각 방법에서 에너지 소모량이 얼마나 감소될 수 있는지를 비교하고 분석한다. 이러한 논의를 통해서 향후 역삼투 공정의 에너지 소모량이 얼마나 더 감소할 수 있을지에 대한 가능성을 평가할 수 있고 나아가서 역삼투 해수담수화 플랜트의 에너지 소모량을 낮추는 명확한 아이디어를 제공할 수 있다.