The Precast concrete(PC) modular structures are a method of assembling pre-fabricated unit modules in the construction site. The essential aim of modular structures is to introduce a connection method that can ensure splicing performance and effectively resist shear strength. This study proposed PC module using a connecting plate that can replace splice sleeves and shear keys used in the conventional PC modular structures. To evaluate the splicing performance and shear capacity of the proposed method, the shear test was conducted by fabricating one monolithic reinforced concrete(RC) beam and two PC modular beams with a shear span-to-depth ratio as variables. The experimental results showed that the shear capacity of the PC modular beam was about 89% compared to that of the RC beam, and showed a failure of the RC beam according to the shear span-to-depth ratio. Therefore, it was considered that the connecting plate effectively transferred the stress between each PC module through the joint and ensure integrity. In addition, the applicability of shear strength equation of ACI 318-19 and Zsutty's equation to PC modular beams were evaluated. Results demonstrated that the improved shear strength equations are needed to consider reduction of shear strength in PC modules.
국내 공동주택 전단벽 구조시스템에 적용되는 감쇠장치는 대부분 인방형 형상으로 적용되고 있다. 인방형 감쇠장치는 좌우 전단벽을 연결하여 커플링 효과 및 추가 감쇠효과를 발휘하여 구조물 내진성능을 증대시킨다. 본 연구에서는 인방형 감쇠장치를 소개하고 감쇠장치가 적용된 구조물의 거동특성을 파악하였다. 제안된 감쇠장치는 힌지 및 변단면 형상으로 감쇠효과를 극대화시킨 구조로 유한요소 해석결과와 실험결과가 잘 일치하여 우수한 내진성능을 발휘하는 것으로 나타났으며, 해당 감쇠장치가 적용된 2차원 및 실제 공동주택 구조물을 대상으로 감쇠효과를 검토한 결과, 감쇠장치 커플링 효과로 기존구조물 대비 모든 구조물에서 내진성능 향상을 도모할 수 있었다. 본 연구에서 검토한 실제 구조물에 대해서는 비선형 정적해석 결과, 강도 및 연성능력이 향상되는 것으로 나타났고, 비선형 동적해석 결과, 층간변형각이 15%~18%, 층가속도가 20%~28%, 밑면전단력이 15%~20% 감소하는 결과를 나타냈다.
For the joint connection of the precast steel grid composite decks, a prefabricated joint which is composed of a concrete shear key and high-tension bolts was already proposed. In this study, for the purpose of increasing the bending stiffness and bending strength of the proposed prefabricated joint section details of the proposed joint are modified, and through experimental tests the bending performance, such as stiffness and strength of a modified joint, are compared with those of the proposed joint.
본 연구는 조적조 치장벽체의 신축과 보강공사에 사용될 수 있는 나선형 긴결철물을 사용하여 내부벽체와 긴결된 치장벽체의 전단거동실험을 행하여 이 벽체의 구조적 성능을 검증하고 적절한 시공간격⋅형태 등을 제안하기 위한 실험연구이다. 본 연구를 통해 벽체의 Rocking거동에 있어서는 나선형 긴결철물을 사용한 벽체가 기존 시공법의 벽체보다 동일 간격에서는 우수한 전단저항능력을 나타내며, 간격이 30%정도 증가하여도 유사한 능력을 발휘한다. 짧은 간격에서의 긴결도는 기존 시공법보다 상당히 높음으로 고층건물의 치장벽체로 연와조 조적체의 적용가능성을 높일 수 있을 것으로 판단된다.