        1.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Because a smart isolation system cannot be used as a base isolation system for tall buildings, top-story or mid-story isolation systems are required. In this study, adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions in comparison with a passive top-story isolation system.
        4,000원
        2.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 스마트 최상층 면진시스템을 적용한 고층건물의 풍응답 제어성능을 검토해보았다. 이를 위하여 77층 초고층 건물을 예제구조물로 선택하였고 풍동실험을 통해서 얻은 풍하중을 사용하여 수치해석을 수행하였다. 예제구조물의 최상층은 FPS 및 MR 감쇠기로 구성된 스마트 면진시스템을 이용하여 주구조물과 분리된다. 주구조물의 동적응답을 저감시키는 것이 스마트 최상층 면진시스템의 가장 중요한 목표이지만 면진된 최상층의 과도한 응답은 구조물을 불안정하게 만들 수 있다. 따라서, 본 연구에서는 면진된 최상층과 주구조물을 효과적으로 제어하기 위하여 스카이훅제어기를 제어알고리즘으로 사용하였다. 제안된 스마트 최상층 면진시스템의 제어성능을 검토하기 위하여 일반적인 수동 최상층 면진시스템의 제어성능과 비교하였다. 수치해석결과 제안된 스마트 최상층 면진시스템을 이용하면 일반적인 수동 최상층 면진시스템에 비해서 면진층의 변위를 효과적으로 줄이면서도 구조물의 응답을 저감시킬 수 있음을 확인할 수 있었다.
        4,000원