검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 7

        1.
        2015.04 KCI 등재 서비스 종료(열람 제한)
        This study is daytime and nighttime runoff image data caused by heavy rain on May 27, 2013 at Oedo Water Treatment Plant of Oedo-Stream, Jeju to compute runoff by applying Surface image velocimeter (SIV) and analyzing correlation according to current. At the same time, current was comparatively analyzed using ADCP observation data and fixed electromagnetic surface current meter (Kalesto) observed at the runoff site. As a result of comparison on resolutions of daytime and nighttime runoff images collected, correlation coefficient corresponding to the range of 0.6~0.7 was 6.8% higher for nighttime runoff image compared to daytime runoff image. On the contrary, correlation coefficient corresponding to the range of 0.9~1.0 was 17% lower. This result implies that nighttime runoff image has lower image quality than daytime runoff image. In the process of computing current using SIV, a rational filtering process for correlation coefficient is needed according to images obtained.
        2.
        2015.04 KCI 등재 서비스 종료(열람 제한)
        This study analyzed the velocimetry of runoff and measured the flood discharge by applying the SIV (Surface Image Velocimetrer) to the daytime and nighttime flow image data with special reference to Seong-eup Bridge at Cheonmi stream of Jeju during the flow by the severe rainstorm on May 27, 2013. A 1000W lighting apparatus with more than 150 lux was installed in order to collect proper nighttime flow image applied to the SIV. Its value was compared and analyzed with the velocity value of the fixed electromagnetic wave surface velocimetry (Kalesto) at the same point to check the accuracy and applicability of the measured velocity of flow. As a result, determination coefficient R2 values were 0.891 and 0.848 respectively in line with the velocity distribution of the daytime and nighttime image and the flow volume measured with Kalesto was approximately 18.2% larger than the value measured with the SIV.
        3.
        2013.05 KCI 등재 서비스 종료(열람 제한)
        Surface Image Velocimetry(SIV) is an instrument to measure water surface velocity by using image processing techniques. Since SIV is a non-contact type measurement method, it is very effective and useful to measure water surface velocity for steep mountainous streams, such as streams in Jeju island. In the present study, a surface imaging velocimetry system was used to calculate the flow rate for flood event due to a typhoon. At the same time, two types of electromagnetic surface velocimetries (electromagnetic surface current meter and Kalesto) were used to observe flow velocities and compare the accuracies of each instrument. The comparison showed that for velocity distributions root mean square error(RMSE) was 0.33 and R-squared was 0.72. For discharge measurements, root mean square error(RMSE) reached 6.04 and R-squared did 0.92. It means that surface image velocimetry could be used as an alternative method for electromagnetic surface velocimetries in measuring flood discharge.
        4.
        2012.02 서비스 종료(열람 제한)
        표면영상유속계는 PIV의 상호상관법을 이용한 유속 산정 원리를 기초로 하여 Fujita and Komura(1994)와 Aya et al(1995)이 수리모형실험이나 일반 하천에서의 유속측정에 적용 할 수 있도록 응용한 것이다. 표면영상유속계가 간편하고 효율적인 유속측정 방법임에도 불구하고 아직까지 표면영상유속계의 상호상관법에 대한 표준적인 방법과 성능 및 측정 불확도가 정립되어 있지 않아 표면영상유속계를 일반인들이 이용하기 어려운 실정이다. 본 연구에서는 표면영상유속계의 상관영역 크기 변화에 따른 오차 분석을 위해 인공영상을 이용한 오차 분석 방법을 제시하였으며 영상내 입자수와 입자크기를 변화시킨 영상들을 제작한 후 상관영역의 크기를 다양하게 변화시키면서 영상 분석을 수행하였고 유속 산정값의 오차를 분석하였다. 또한 각 상관영역내 명암값 분포를 이용하여 최소 상관영역 크기 결정 기준을 제시하고자 한다. 분석 결과 영상내 입자밀도 평균이 0.5 이상일 경우에는 입자 크기 보다 상관영역의 크기를 크게 결정한다면 오차를 크게 줄일 수 있음을 확인하였다. 또한 입자수 밀도 평균이 0.5 보다 작은 경우는 가능한 상관영역의 크기를 크게 하여 상관계수가 1에 가깝도록 결정하면 오차를 줄일 수 있는 것으로 나타났다.
        5.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        표면영상유속계(SIV)는 영상 분석 기법을 이용하여 하천의 표면유속을 측정하고, 이를 토대로 유량을 산정하는 시스템이다. 본 연구에서는 고정식 표면영상유속계(FSIV) 시스템을 달천 수전교에 설치하여 실시간으로 연속적인 유량 측정을 실시하였다. 수전교에 적용된 FSIV의 하드웨어 시스템은 영상 획득을 위한 2대의 디지털 카메라와 컴퓨터, 그리고 수위 측정을 위한 초음파 수위계로 구성된다. 이 현장 장비들에서 획득된 실시간 영상과 수위 자료는 무선인터넷을
        6.
        2008.08 KCI 등재 서비스 종료(열람 제한)
        표면 영상 유속계(SIV, Surface Image Velocimetry)는 영상 처리 기술을 이용하여 수표면의 유속을 측정하는 장비이다. 유속 측정의 정밀도를 높이기 위해서는 화질이 좋고, 왜곡이 적은 영상을 획득하는 것이 매우 중요하다. 트럭에 장착된 기중기를 이용하는 차량탑재형 표면 영상 유속계는 왜곡이 적은 영상을 얻는 좋은 방법이 될 수 있다. 이 때, 기중기의 흔들림 때문에 획득된 영상이 흔들리는 문제가 발생하며, 영상의 흔들림을 보정하여 유
        7.
        2008.07 KCI 등재 서비스 종료(열람 제한)
        표면영상유속계(SIV)는 영상 처리 기술을 이용하여 수표면의 유속을 측정하는 장비이다. 표면영상유속계는 하천의 유속을 매우 간편하게 측정할 수 있도록 한다. 그러나, 표면영상유속계를 이용하여 유량을 산정하고자 할 경우, 하천 표면의 평면 측량 자료와 하천의 단면 측량 자료가 반드시 필요하다. 이 때문에 표면영상유속계의 간편성과 유용성에도 불구하고, 이용자들이 쉽게 이용하기 어렵다는 그릇된 인식을 줄 수 있다. 만일 효율적이고 간편하게 하천의 평면을 추정