        1.
        2008.03 구독 인증기관 무료, 개인회원 유료
        An experimental real-time hybrid method, which implements the wind response control of a building structure with only a two-way TLMD, is proposed and verified through a shaking table test. The building structure is divided into the upper experimental TLMD and the lower numerical structural part. The shaking table vibrates the TLMD with the response calculated from the numerical substructure,which is subjected to the excitations of the measured interface control force at its top story and an wind-load input at its base. The results show that the conventional method can be replaced by the proposed methodology with a simple installation and accuracy for evaluating the control performance of a TLMD
        4,000원
        2.
        2008.03 구독 인증기관 무료, 개인회원 유료
        In this paper, a two-way tuned liquid mass damper(TLMD) using a tuned liquid column damper(TLCD) and a rubber-bearing-type tuned mass damper(TMD) was manufactured for controlling two-way direction acceleration responses of a high-rise building structure. The proposed controlling device behaves as a tuned liquid column damper in one direction and as a tuned mass damper in the other direction. In this study, Performance evaluation of the downscaled model is conducted. The results show that the two-way controllability is behaved independently each other and realscale TLMD applicable to the high-rise building can be designed.
        4,000원