At high temperatures, molten salt has heat transfer properties like water. Molten salt has the characteristics of a strong natural circulation tendency, large heat capacity, and low thermal conductivity. Unlike sodium, molten salt does not react explosively exothermically with air. However, molten salt has a strong tendency to corrode materials, and its properties are easily changed by a sensitive reaction to oxygen and moisture. Therefore, it is necessary to study material corrosion properties and chemical control methods for nuclear fuel salts, which are eutectic mixtures. In this study, the optimal operation method of the thermal convection loop is established to perform the experiments on the molten salt. The process describes briefly as follows. The operation step consists of preparation, purification, transportation, and operation. In the preparation, the step checks the entire structure and equipment (TC, blower, vacuum pump, etc.). And melt the salt mixture at a high temperature (670°C) slowly in the purification step. Before injecting the molten salt, the surface temperature of the entire loop must retain temperature (about 500°C) constantly. Completely melted molten salt in the melting pot is flow along the pipe of the thermal convection loop in the transportation step. Lastly, the convection of molten salt goes to keep by the temperature difference. The thermal convection loop can be utilized for various experiments such as corrosion tests, component analyses, chemistry control, etc.