검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        3.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, graphene oxide(GO) was used as drug carriers to amorphize poorly watersoluble drugs via a co-spray drying process. Two poorly water-soluble drugs, fenofibrate and ibuprofen, were investigated. It was found that the drug molecules could be in the graphene nanosheets in amorphous or nano crystalline forms and thus have a significantly enhanced dissolution rate compared with the counterpart crystalline form. In addition, the dissolution of the amorphous drug enwrapped with the graphene oxide was higher than that of the amorphous drug in activated carbon (AC) even though the AC possessed a larger specific surface area than that of the graphene oxide. The amorphous formulations also remained stable under accelerated storage conditions (40°C and 75% relative humidity) for a study period of 14 months. Therefore, graphene oxide could be a potential drug carrier and amorphization agent for poorly water-soluble drugs to enhance their bioavailability.
        4,000원
        4.
        2005.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Single-pass flow-through (SPFW) 방법에 의한 유리고화체의 용해율 측정에서 정밀도를 구하기 위하여 연구소간 실험프로그램의 하나로서 붕규산유리고화체의 정용해율을 구하였는데, 이 SPFT 방법은 American Society for Testing and Materials (ASTM)에서 표준화를 위하여 작성되었다. 이를 위해 100/200 mesh 크기의 모의 저방사능 유리고화체 분말시료를 , 알곤 분위기에서 SPFT 방법으로 리튬 완충용액 (pH=10)을 이용하여 용해실험을 시도하였다. 얻어진 용출액 중 규소와 붕소의 농도에 따라 용해율의 변화를 구한 결과, 유리의 정용해율이 부근으로 나타났다.
        4,000원
        5.
        2021.05 KCI 등재 서비스 종료(열람 제한)
        The dissolution of ionized gas in dielectric barrier plasma, similar to the principle of ozone generation, is a major performance-affecting factor. In this study, the plasma gas dissolving performance of a gas mixing-circulation plasma process was evaluated using an experimental design methodology. The plasma reaction is a function of four parameters [electric current (X1), gas flow rate (X2), liquid flow rate (X3) and reaction time (X4)] modeled by the Box-Behnken design. RNO (N, N-Dimethyl-4-nitrosoaniline), an indictor of OH radical formation, was evaluated using a quadratic response surface model. The model prediction equation derived for RNO degradation was shown as a second-order polynomial. By pooling the terms with poor explanatory power as error terms and performing ANOVA, results showed high significance, with an adjusted R2 value of 0.9386; this indicate that the model adequately satisfies the polynomial fit. For the RNO degradation, the measured value and the predicted values by the model equation agreed relatively well. The optimum current, gas flow rate, liquid flow rate and reaction time were obtained for the highest desirability for RNO degradation at 0.21 A, 2.65 L/min, 0.75 L/min and 6.5 min, respectively.
        6.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to investigate the possibility of utilizing various types of nozzles and gas-liquid mixers to increase the dissolution rate of plasma gas containing ozone generated in a dielectric barrier plasma reactor. After selecting the air atomizing nozzle with the highest gas dissolution rate among the 13 types of test equipment, we investigated the influence of the operating factors on the air atomizing nozzle to determine the optimal plasma gas dissolution method. The gas dissolution rate was measured by a simple and indirect method, specifically, the measurement of KLa instead of direct measurement of ozone concentration, which requires a longer analysis time. The results showed that the KLa value of the simple mix of air and water was 0.372 min-1, Which is 1.44 times higher than that (0.258 min-1) of gas emitted from a normal diffuser. Among the nozzles of the same type, the KLa value was highest for the nozzle having the smallest orifice diameter. Among the 13 types of devices tested, the nozzle with highest KLa value was the M22M nozzle, which is a gas-liquid spray nozzle. The relationship between water circulation flow rate and KLa value in the experimental range was linear. The air supply flow rate and KLa value showed a parabolic-type correlation, while the optimum air supply flow rate for the water circulation flow rate of 1.8 L / min is 1.38 times.