We established pretreatment method of solidified cement ion-exchange resin samples generated before 2003 in nuclear power plants for measurement of non-volatile radionuclide activity. A microwave digestion system (MDS) with mixed acid (HCl-HNO3-HF-H2O2) was used to dissolve cement and to desorb non-volatile elements such as Ce, Co, Cs, Fe, Nb, Ni, Re, Sr and U from mixed ion-exchange resin. The content of Ce, Co, Fe, Nb, Ni, Re, Sr, U and Cs after pretreatment of cement plus mixed ion-exchange resin was measured by ICP-AES and ICP-MS, respectively. As iron and strontium are also present in cement, their content after dissolving a certain amount of cement was measured by ICP-AES. All elements except Nb were quantitatively recovered. Especially since the Nb recovery was low at 72.0±2.5%, the MDS following addition of the mixed acid to the resin was operated once more for desorbing Nb from it. Finally the recovery of Nb was over 95%. This sample pretreatment method will be applied to solidified cement ion-exchange resin samples generated in nuclear power plants for assessment of radionuclide inventory.
본 논문은 범용성 기기를 기반으로한 가속도계로 라즈베리파이 4B 기반 MEMS형 가속도계 ADXL345와 iPhone 12 pro 내 장형 가속도계를 사용하여 다자유도 축소 모형 구조물의 응답을 계측하고 그 결과를 IEPE타입 가속도계와 비교하여 계측 유효성을 확 인하고자 하였다. 1~3층 모형 구조물 최상층에 충격해머로 가진하였으며 각 층의 가속도를 측정하였다. 시간영역에서 모든 가속도계 의 계측값이 대체적으로 유사한 결과를 나타냈으며 진동수영역에서 모드진동수 또한 유사하게 나타났다. 감쇠비와 모드형상 추정에 있어서 라즈베리파이 기반 ADXL345보다 iPhone 12 pro가 더 정확한 결과를 보였으나 대체적으로 유사하게 나타났다. 실험 결과를 바 탕으로 라즈베리파이 기반 ADXL345와 iPhone 12 pro 가속도계의 구조물 식별 유효성을 확인하였다.
농업용 노외작업 기계는 작업속도가 변이하므로 경운 시비 방제 파종 작업등에서 주행속도를 정확하게 측정할 필요가 있다. 도플러 레이더는 포장에서 속도측정의 신뢰성이 있어 견인효율 또는 변량제어 연구 등에서 사용될 수 있을 것으로 판단된다. 따라서 본 연구에서는 도플러 레이더 속도계를 이용하여 주행속도를 측정할 때 콘크리트 견고지면에서 보정된 기준 변환계수를 포장실험에서도 적용이 가능한지에 대한 엄격한 통계적 검토와 검증을 수행하였다. 견고지면에서 얻은 기준 변환계수를 비교군으로 포장실험의 결과를 검증하기 위하여 Proc GLM을 사용하였다. 완전모델 의 분산분석 결과에서 유의하지 않은 교호항을 제거한 주 변수모델에 대하여도 유의하지 않았다. 사후분석에서 보수적이고 엄격한 Scheffe 방법으로 민감한 계수를 검정하였고 또한 유의하지 않았다. 기준 변환계수를 비교군으로 하여 대비처리(contrast) 하였고 유의하지 않았다. 견고지면에서 평가한 기준 변환계수(a0=0.0396)와 기준절편(y0=-0.0235)을 바탕으로 평가한 변환계수(a)의 절대오차(Erra)는 –0.415×10-3 이었고, 퍼센트 오차는 –1.18% 였다. 따라서 기준 변환계수는 포장작업의 주행속도의 환산계수로 사용되어도 측정치에 심각한 오차를 초래하지 않을 것이다.
This paper aims to analyze the scores assigned to compositions of Korean as a foreign language (KFL) in terms of the many-facet Rasch measurement (MFRM) model. The MFRM computer program Facets has recently been updated and this research uses it in order to investigate the scoring reliability of KFL writing test. For the research data the Korean compositions written by 270 KFL learners were collected and rated by eleven Korean raters. At first a brief theoretical basis for the Facets is introduced based on the MFRM model. Then focusing on the raters’ characteristics such as rating consistency and fitness in terms of the rating scheme of content/organization and language, the collected scores of KFL compositions are analyzed and the analysis results are interpreted. As a result, a few cases of unreliable scoring of Korean raters are identified, but it appears that the ratings of Korean raters for a standardized KFL writing test are generally reliable. Finally it is suggested that the Facets program of MFRM offer many potential advantages for validating the scoring reliability of Korean writing assessment.
Purpose: This study aimed to investigate the agreement and test-retest repeatability of two methods for measuring magnitude of toric lens rotation. The two methods assessed were using the slit lamp biomicroscope and a newly developed software tool for the iPhone platform called “Toric App” which uses the built-in camera of the iPhone. Methods: Thirty three participants (66 eyes) wore toric lens (silicon hydrogel material with the prism ballast design) both eyes. Two operators, both registered optometrists, measured toric lens rotation using the two methods. One operator used the same method twice for an assessment of test-retest repeatability of each method. Inter- and intra-operator agreement and repeatability were assessed using Bland-Altman analysis. Results: The ninety-five percent confidence intervals (95% CIs) for the limits of agreement between the silt-lamp biomicroscope and Toric App methods was ±9.1 degrees. Measurements using the two different methods showed no statistically significant mean difference (0.40) (paired t-test, p=0.32). Inter-observer agreement of lens rotation was ±7.9 degree (95% CIs) using the slit-lamp microscope and ±7.8 degree using the Toric App. Intra-observer repeatability was ±6.6 degree using the slit lamp microscope and ±6.8 using the Toric App. Conclusions: The results should be considered in view of the fact that toric lenses are not static but move with the blink thus the location of the reference point is unlikely to be at exactly the same location at the different measurement times. Despite this source of variability in the results, the newly developed software tool for iPhone provides clinically comparable performance to slit lamp biomicroscope measurement which does not appear to be operator dependent. This software tool may be a useful for those optometric practices have limited access to a slit-lamp biomicroscop
목적: 본 연구는 운동선수의 심리기술과 심리기법을 통합적으로 측정할 수 있는 도구를 개발하고, 개발된 측정도구의 타당도와 신뢰도에 대한 증거를 제공하는데 목적이 있다. 방법: 운동선수의 슈퍼심리기술(BIG 7 심리기법, SUPER 5 심리기술)을 토대로 전문가 회의를 통해 5점 Likert식 측정도구를 구성하였다. 연구대상은 총 597명의 운동선수였으며, 개발된 측정도구의 구조타당성을 검증하기 위하여 탐색적 요인분석과 확인적 요인분석을 실시하였고, 타 도구와의 상관분석과 경기력수준에 따른 차이검증을 실시하였다. 결과: 탐색적 요인분석결과 과정단서요 인이 삭제되었으며, 확인적분석 결과에서도 11개 요인 구조를 지지하는 것으로 나타나 최종 개발된 측정도구는 11개요인 37문항으로 구성되었다. 또한, 추가분석을 통해 개발된 측정도구에 대한 타당도와 신뢰도에 대한 증거를 제시하였다. 결론: 개발된 심리기술과 심리기법의 통합적 측정도구는 운동선수들의 심리기술과 심리기법을 측정하고자 할 때 신뢰할 수 있고, 유효한 측정도구이다.