검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2018.04 구독 인증기관·개인회원 무료
        Purpose:Recently, studies have been conducted to improve the signal intensities by increasing the filling factor, which is the volume ratio of the subject in the coil using a compensating material that does not appear as a magnetic resonance signal. Previous studies note that the magnetic susceptibility difference between the air and the compensation material should be minimized. Therefore, in this study, we tried to investigate and compare the materials that can reduce the susceptibility differences most effectively among various materials similar to human tissue density. Materials and Methods:The customized phantom was constructed using 7 different compound(borax powder, saline solution, sulfur powder, silicon power, graphite powder, wheat flour and silicon pad). A Bland-Altman plot was used to measure the magnetic susceptibility difference between the air and the phantom compound. Image acquisition was performed using a 3.0 T magnetic resonance imaging system (Skyra, Siemens, Germany) and a 15-channel head coil. Validation of a quantitative susceptibility mapping acquisitionw were carried out on T2 and T2* apping using Matlab (Ver.7.10, Mathworks, USA) and Image J (Ver.1.47v, NIH, USA) program. Results:The mean values of graphite (upper: -88.4, center: -100.5, lower: -101.6) and silicone (upper: -74.0, center: -37.1, lower: -96.6) were appeared negative which meant the susceptibility differences were higher than air. In contrast, wheat flour(Upper: 9.0, center: 0.3, lower: 11.3), silicon pad (upper: 13.9, center: -0.7, lower: 13.5), saline (upper: 11.9 , center: 1.0, lower: 16.3), borax (upper: 19.1, center: 1.2, lower: 13.6)and sulfur (upper: 19.0, center: 1.1, lower: 13.9)showed positive value which meant lower susceptibility difference compared to air. As a compensating material to overcome difference in susceptibility uniform performance and less deviation were observed in the compounds other than the graphite and silicon regardless of their position. Conclusion:The magnetic susceptibility is the intrinsic physical quantity of the elements in the periodic table such as mass and spin. In other words, when an element is exposed to an external magnetic field, it is a measure of how much the element is magnetized. Therefore, in selection of the magnetic susceptibility compensating material, it is important to select one the with the small magnetic susceptibility difference compared to air. In this study, the differences of susceptibility among wheat flour, silicon pad, physiological saline, borax and sulfur were observed to be appropriate. Increasing the filling factor with magnetic susceptibility compensating materials proposed in this study can improve the signal intensities.
        2.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 3개 이상의 기둥그룹에 대해서도 일반적으로 적용 가능한 기둥축소량의 최적보정기법을 제안하고, 이를 실제 시공된 건물에 적용하여 그 적용성을 평가하였다. 제안된 최적보정기법은 성능 및 시공상의 제약조건을 만족하면서 보정개소를 최소한으로 할 수 있는 층그룹 및 이때의 보정량을 산정하며, 상대보정뿐만 아니라 절대보정을 고려한 혼합보정도 가능하다. 최적보정에는 시뮬레이티드 어닐링(simulated annealing)이 주요 알고리즘으로 사용되었다. 제안된 기법을 실제 축소량 보정이 수행된 61층 건물에 적용한 결과, 보정량을 쉽게 산출할 수 있고 또한 실무방식보다 보정개소를 줄일 수 있어 적용성이 뛰어남을 확인하였다.
        4,000원