검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Modified dapped end, precast prestressed double-tee slabs were considered in this research. It can facilitate insertion of service ducts at the dapped ends. The total depth of the floor slab may be reduced. In addition, the underside of the double-tee slab showed simpler appearance. Static three-point shear loading test was performed on full-scale specimens. And three modified single-tee slabs were analyzed by strut-tie model method. The specimen failed during the test in the same location as predicted by the strut-tie analytical model. The analysis of experimental results in comparison to the analysis results revealed that the experimental failure loads manifested 108% of analytical failure loads on the average.
        4,000원
        2.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 깊은 보의 전단강도 산정을 위해 현행 미국콘크리트학회(ACI) 및 캐나다표준규격협회(CSA), 유럽콘크리트위원회(CEB-FIP)의 설계기준은 스트럿-타이 모델을 이용할 것을 제안하고 있지만 설계의 품질이 설계자가 구성한 트러스 모델 적합성에 크게 좌우된다는 특징을 가지고 있다. 따라서 본 논문에서는 내부 트러스 모델에 따른 현행 ACI, CSA 및 CEB-FIP의 콘크리트 깊은 보 설계기준의 타당성을 홍성걸 등에 의해 제안된 콘크리트 소성학에 근거한 전단강도식의 예측치와 비교함으로써 평가한다. 비교 결과 ACI, CSA 및 CEB-FIP의 스트럿-타이 모델에 의해 설계된 깊은 보의 경우 내부트러스 모델이 전단강도 예측에 중요한 영향을 미치는 것으로 나타났으며 CEB-FIP의 경우 가장 높은 스트럿 강도 예측치를 보였다.
        4,000원