A number of studies on airborne pollutants and microorganisms using ultraviolet sterilization have been conducted. Countermeasures are also needed to be taken against contamination and damage that occur on indoor surfaces in addition to indoor air. In this study, a method to predict UV-C intensity distribution using radiance calculation was introduced for the purpose of surface sterilization using UVGI systems and compared with the measured UVC intensities in a kitchen model room. The results of calculations showed a similar distribution of ultraviolet intensity with the measured intensities, although there was some discrepancy, probably due to different reflectance of building materials. And some bacteria and viruses occasionally identified in kitchens were predicted to be sterilized 99.9% only after about 30 minutes of UV-C irradiation with the figure 90% for fungi. The sterilization performance of UVGI and exposure time to UV-C were reasonably predicted using the radiance calculation method, and UV sterilization can be achieved with great effect even after a short period of time.
포장에서 생육된 잔디 포복경을 이용한 Agrobacterium 형질전환에 있어서 큰 제한인자였던 곰팡이 오염을 제거할목적으로 포복경 조직에 대한 새로운 살균법을 개발하고자하였다. 여러 가지 살균방법 중에서 30% NaOCl로 15분간처리한 다음 0.1% HgCl2로 25분간 처리 했을 때 포복경절편체의 생존율이 높았으며, 0.1% HgCl2로 처리시 800mbar의 진공처리를 5분간 실시했을 때 가장 효과적이었다.또한 Agrobacterium과 공동배양 시 2.5 mg/l의 amphotericinB를 첨가해 준 배지에서 배양했을 때 가장 높은 생존율을나타내었다. AmB의 처리는 Agrobacterium의 생장에 영향을 미치지 않았다. 또한 살균된 포복경으로 부터 신초의재분화에도 영향을 미치지 않았으며 곰팡이 오염만을 효율적으로 억제하는 것으로 나타났다. 이러한 결과는 포장에서 대량으로 생육시킨 잔디 포복경을 이용한 Agrobacterium형질전환 시 그 효율을 증가시키는데 큰 기여를 할 것으로추측된다.