        41.
        2015.10 서비스 종료(열람 제한)
        This paper indicated the seismic performance evaluation of coupling beam designed by ACI 318 11 and SFRC(Steel fiber reinforced concrete). In this study, SFRC coupling beam added steel fiber of 1.5 %. Teste results indicated that coupling beam reinforced by SFRC shown outstanding absorb energy capacity and stiffness degradation than concrete coupling beam by bridge effect of steel fiber.
        42.
        2014.04 서비스 종료(열람 제한)
        This paper describes the analysis results of coupling beams using steel fiber reinforced concrete for comparison with measure behaviors. Analysis is performed by the finite element analysis program, Vector 2. The results show possibility that relieve complex detail of diagonally reinforced coupling beam.
        43.
        2014.04 서비스 종료(열람 제한)
        This paper describes the structure performance of glass fiber-reinforced polymer (GFRP) shear connectors for insulated concrete sandwich panels (CSP). In this study, experiments are conducted to investigate the physical features of insulated CSP with GFRP shear connectors with varying shape and specification of GFRP shear connectors, and types of insulations. Test results indicate that developed GFRP shear connector has a significant effect on structure performance of insulated CSP.
        44.
        2014.04 서비스 종료(열람 제한)
        The purpose of this study was to effects on flexural performance of SFRC prism with different fiber volume fraction. The test variables such as aggregate maximum size(8, 13, 20mm) and steel fiber volume faction(0, 1, 2%). Specimen size is 100×100×400mm and tested in for points loading. Test results indicated that increase the fiber volume fraction increase with flexural strength and smaller aggregate size more than higher performance with concrete.
        45.
        2014.04 서비스 종료(열람 제한)
        This paper described the correlation between compressive and flexural toughness of SFRC(Steel fiber reinforced concrete). Experiment was conducted to evaluate the correlation SFRC specimens with different aggregate sizes (8mm, 13mm, 20mm) and fiber volume fraction (0%, 0.5%, 1.0%, 1.5%, 2.0%). For the measurement of compressive and flexural toughness using ACI committee and ASTM C 1018 procedure. Test results indicated that the addition of steel fiber improves flexural and compressive performance of high-strength concrete. Also smaller aggregate size improve the mechanical properties of high fiber volume fraction SFRC.
        47.
        2013.10 서비스 종료(열람 제한)
        This paper provides Shear Performance Evaluation of Squat Shear Wall on Aspect Ratio of Slit. The main variables of paper were vertical slit and slit length. Slit height analysis results by lengthening the slit height was reduced according to the strength and stiffness, the maximum displacement was increased.
        48.
        2013.10 서비스 종료(열람 제한)
        This paper addresses failure modes of steel fiber coupling beams containing steel fiber. It shows that steel fiber of coupling beams efficiently controlled increase of crack width by bridge action.
        49.
        2013.10 서비스 종료(열람 제한)
        This paper addresses analysis using vector2 program of steel fiber coupling beams containing steel fiber. It shows that steel fiber of coupling beams efficiently controlled increase of crack width by bridge action.
        50.
        2013.10 서비스 종료(열람 제한)
        In this study, to Assess the Structural performance of Reinforced Concrete Shear Wall with different Slit Length. Variable of analysis is slit length(0, 600, 1200, 1500, 2400mm), showed excellent accuracy. Maximum load is decreased when the slit length increased. But Side sway of maximum load is increased when the slit length increased.
        51.
        2013.10 서비스 종료(열람 제한)
        The effects of maximum aggregate size on mechanical properties of high-strength steel fiber reinforced concrete (SFRC) were investigated in this work. Test main variable is maximum aggregate size (8 and 20mm). The cylinder specimens was casted for compressive test and the prism specimens was tested under four points loading. Test results indicated that the addition of steel fiber improves compressive and flexural behavior of high-strength concrete. Also smaller aggregate size improve mechanical properties of high fiber volume fraction SFRC.
        52.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        This paper describes an experimental program to investigate the shear behavior of insulated concrete sandwich panels (CSPs) with different types of GFRP shear connector. The study included testing of 13 insulated CSP specimens with two types of surface conditions for extruded polystyrene (XPS) insulation and various shapes of shear connectors. All specimens were loaded in direct shear by means of push-out and were consist of three concrete panels, two insulation layer and four rows of GFRP shear connectors. Load-relative slip between concrete panel and insulation response of CSP specimens has been established through push-out shear test. Test results indicate that the surface condition of insulation has a significant effect on the bond strength between concrete panel and insulation. The specimen used XPS foam with 10mm deep slot shows higher bond strength than those used XPS foam with meshed surface. Corrugated GFRP shear connectors show equivalent strength to grid GFRP shear connectors. Cross-sectional area and embedded length of shear connector have a notable effect on overall response and inplane shear strength of the CSP specimens.
        53.
        2013.04 서비스 종료(열람 제한)
        This paper describes the flexural performance of concrete and strain-hardening cement based composite (SHCC) beams reinforced with normal and high-strength steel bar to evaluate the effect of reinforcing bar strength and cement composite type. The present investigation shows the potential of high-strength structure materials used of high-strength reinforcing bars with SHCC. And superior mitigation of crack-damage is observed reinforced SHCC beams than reinforced concrete beams
        54.
        2013.04 서비스 종료(열람 제한)
        This experimental study examines the test results on the flexural behavior of strain-hardening cement composite (SHCC) with two types of Shrinkage Reducing Admixture (SRA). An influence of SRA on the flexural behaviors of SHCC mixes was observed.
        55.
        2013.04 서비스 종료(열람 제한)
        This paper describes evaluaties the mechanical characteristics of high strength steel fiber-reinforced concrete(SFRC) with maximum size of coarse aggregate. The test variables such as aggregate maximum size(8, 13, 20mm) and steel fiber volume faction(0, 1.5%). The test results indicate, SFRC of smaller aggregate size is expected to prvention of brittle fracture and promote of compression toughness.
        56.
        2013.04 서비스 종료(열람 제한)
        This paper present results from effect of fiber volume fraction on direct shear property of steel fiber reinforced concrete(SFRC). Steel fiber with crimped end was used this work. Principal variable is fiber volume fraction; 0, 0.5, 1, 1.5, 2%, and aggregate size; 8, 13, 20mm. Specimen cross-sectional is 100 x 100 x 400mm. In order to induce the shear failure 2mm notch was sawed all around the specimen. Test result, there are little different between the aggregate size, and the improvements in shear strength of SFRC were more significant for 1% steel fiber volume fraction.
        57.
        2012.05 서비스 종료(열람 제한)
        This paper describes the structural behavior of insulated concrete wall panels with no-bond stress insulation. That panels reinforced with fiber reinforced polymer (FRP) truss shear connector to achieve composite action of inner and outer concrete wythes. Main test variable is bond stress. According to the test result, the shear capacity of increased due to bond stress and reinforced with FRP truss shear connector.
        58.
        2012.05 서비스 종료(열람 제한)
        This paper describes the structural behavior of insulated concrete wall panels with EPS insulation. That panels reinforced with Fiber Reinforced Polymer (FRP) truss shear connector to achieve composite action of inner and outer concrete wythes. Main test variables are FRP cross section, width and picth. According to the test result, the shear capacity of increased due to reinforced with FRP truss shear connector. And width 12, 18 mm shear connector need more than 30 mm experiments about reclamation deep.
        59.
        2012.05 서비스 종료(열람 제한)
        This study was shear strength of insulated concrete sandwich panels with tress shear connector. Specimens with results XPSSTG insulation than the EPS insulation was good in the Shear Strength. The maximum displacement is better than the EPS specimens and that of the specimens XPSSTG trends that appear are considered.
        60.
        2012.05 서비스 종료(열람 제한)
        This experimental study evaluates of seismic performance on strain-hardening cement-based composite (SHCC). The objective of this study is to evaluate of cross-sectional reduction (1400×800×70 and 1120×520×40㎜) and design compressive strength level (45 and 50 MPa). The experimental results as cross-sectional reduction, peak loads are not significantly different. but energy area is decrease.