검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 11

        1.
        2022.07 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Single OLED and tandem OLED was manufactured to analyze the electroluminescence characteristics of DC driving, AC driving, and full-wave rectification driving. The threshold voltage of OLED was the highest in DC driving, and the lowest in full-wave rectification driving due to an improvement of current injection characteristics. The luminance at a driving voltage lower than 10.5 V (8,534 cd/m2) of single OLED and 20 V (7,377 cd/m2) of a tandem OLED showed that the full-wave rectification drive is higher than that of DC drive. The luminous efficiency of OLED is higher in full-wave rectification driving than in DC driving at low voltage, but decrease at high voltage. The full-wave rectification power source may obtain higher current density, higher luminance, and higher current efficiency than the AC power source. In addition, it was confirmed that the characteristics of AC driving and full-wave rectification driving can be predicted from DC driving characteristics by comparing the measured values and calculated values of AC driving and full-wave rectification driving emission characteristics. From the above results, it can be seen that OLED lighting with improved electroluminescence characteristics compared to DC driving is possible using full-wave rectification driving and tandem OLED.
        4,000원
        3.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, we analyzed the characteristics of nitrogen oxide and fine particulate matter concentration for boarding positions at the bus stop of an exclusive bus lane, using a correlation analysis and a generalized linear model. METHODS : To analyze the air pollution characteristics for boarding positions at the bus stop, data on nitrogen oxide, fine particulate matter concentration, relative humidity, temperature, wind speed, solar radiation, and bus traffic volume were acquired. Using the collected data, a correlation analysis for nitrogen oxide and fine particulate matter was carried out for each boarding position. Additionally, the prediction models for each pollutant were estimated using a generalized linear model, to analyze their characteristics. RESULTS : Correlation analysis revealed that relative humidity and bus volume were positively correlated with both nitrogen oxide and fine particulate matter concentrations in all boarding positions, whereas temperature, wind speed, and solar radiation were negatively correlated. Based on the estimated models from the generalized linear model, the nitrogen oxide concentration at the first measurement point was found to be affected by relative humidity, temperature, and bus volume, whereas at the second measurement point, it was found to be affected by relative humidity, temperature, and solar radiation. Additionally, all factors were significant for fine particulate matter concentration at both boarding positions. CONCLUSIONS : The analytical results indicated that the characteristics of nitrogen oxide and fine particulate matter concentration at the bus stop of an exclusive bus lane varied significantly depending on the boarding positions. Particularly, it was found that the correlation between solar radiation, and nitrogen oxide and fine particulate matter was different because of the conversion of nitrogen oxide to fine particulate matter.
        4,000원
        4.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to determine the characteristics of nitrogen oxide (NOx) concentration in an exclusive median bus lane station. The hourly variations of NOx concentration and the effect of traffic volume on NOx concentration were analyzed using NOx measurement data and the number of vehicles at the station. METHODS : Data were collected using the chemiluminescence method for NOx concentration. Atmospheric information and traffic volume of buses were collected from the Korea Meteorological Administration and Bus Information System, respectively. RESULTS : As a result, the NO2 concentration in the test section was found to have a strong correlation with those in the atmospheric measurement station located near the test-bed. In addition, the average NOx concentrations in the test section were significantly higher than those of the other monitoring stations due to bus emissions. The average NOx concentration in the exit section was higher than that in the entry section owing to the vehicle’s frequent stops and fuel consumption due to acceleration. During the measurement period, the average NOx concentration was measured as approximately 33 % higher in the exit section than in the entry section. In addition, the NOx concentration at the bus station was found to increase as the bus dwell time increased, rather than the number of bus passages. CONCLUSIONS : This study provides clear characteristics of the NOx correlations with traffic information in an exclusive median bus lane station. It was shown that the NOx concentration at the bus station increased as the number of passes and bus dwell time increased. According to the coefficient of determination, the dwell time is more closely correlated to the NOx concentration at the bus station than the number of bus passes, indicating that it is a better parameter for predicting NOx concentration at bus stations.
        4,000원
        5.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, the characteristics of fine particulate matter (PM2.5) concentrations under different weather conditions of different types of bus stops, such as enclosed-type and open-type bus stops, were analyzed using statistical methods. METHODS : Data was collected inside and outside an enclosed bus stop on sunny and rainy days to compare and analyze the characteristics of fine particulate matter concentration in the target bus stop. The probability distributions were estimated for each data point using the Anderson–Darling test. Based on the estimated probability distributions, probability density functions were computed, and the values were used to estimate and compare probability for each air quality index inside and outside the bus stop under different weather conditions RESULTS : For the results of descriptive statistics, the average concentrations of fine particulate matter inside and outside the bus stop were 42.296 and 35.482 μg/m3 on a sunny day and 40.831 and 39.321 μg/m3 on a rainy day, respectively. Results of the statistical method, obtained using the Anderson-Darling test, indicate that the probability of the air quality index inside the bus stop reaching high concentrations on a sunny day was "high" or "very high," compared to that outside the bus stop. However, on rainy days, the differences in fine particulate matter concentrations inside and outside the bus stops were difficult to identify based on statistical evidence. CONCLUSIONS : It was found that the open-type bus stop had an advantage of preventing fine particulate matter effects on sunny days, compared to the enclosed-type bus stops. Furthermore, there were slight differences in fine particulate matter concentrations inside and outside the bus stop on a rainy day because of atmospheric flow and stormwater.
        4,000원
        7.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 생체모방형 비대칭 분리막 제조방법인 사각펄스양극산화법의 비대칭성 한계를 극복하기 위해 최근 보고된 셀렌산 전해액을 이용하고 표면개질에 따른 정류특성을 평가하였다. 분리막의 비대칭 원뿔형 채널은 최소직경이 10 nm이고 최대직경이 50 nm이며 길이가 5 μm이었다. 분리막의 정류특성은 기존 황산 전해액에서 제작된 것보다 높았으며 +1 V에서의 전류가 -1 V일 때보다 최대 2.9배를 나타내었다. 또한, 실란화 반응을 이용한 표면개질을 통해 술폰산기를 도입한 분리막은 반대로 -1 V에서의 전류가 +1 V일 때보다 전류의 최대 4.2배인 정류특성을 나타냈다. 실험에 대한 이론적 증명은 2D 모델에 수치해석 결과를 제시함으로써 뒷받침되었다. 본 연구의 결과는 서로 다른 정류방향을 갖는 두 종류의 이온 정류 분리막을 손쉽게 제작할 수 있는 방법을 제시하며 이온의 이동을 제어하기 위한 다양한 연구 분야에 활용될 수 있을 것으로 기대된다.
        4,000원
        8.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The purpose of this study is to compare the concentrations of fine particulate matter (PM2.5) at different types of roadside bus stops in an urban environment, and analyze the tendencies in PM2.5 concentrations according to the air quality index. METHODS : To compare and analyze the characteristics of fine particulate matter at roadside bus stops, we collected data such as PM2.5 concentration, temperature, humidity etc., and performed a comparative analysis of their concentration levels at different types of bus stops (a partially closed bus stop with a front and back partition, a partially closed bus stop with only a back partition, and a bus stop with an open space). In addition, the daily variation in fine particulate matter concentration was analyzed. RESULTS: The average daily concentration levels of fine PM2.5 in the target area for a partially closed bus stop with a front and back partition, a partially closed bus stop with a back partition, and a bus stop with an open space were 18.40㎍/㎥ to 108.27㎍/㎥, 22.81㎍/㎥ to 135.51㎍/㎥, and 16.62㎍/㎥ to 81.52㎍/㎥, respectively. According to air quality index levels during the target measurement period, the bus stop with an open space had the least concentration levels of PM2.5 compared to the other bus stops. Furthermore, this study revealed that the PM2.5 concentration levels usually increased during the peak hour period in the morning and gradually increased after 2 pm until the end of the peak hour period at night, regardless of the bus stop type. CONCLUSIONS: Based on the results of this study, we demonstrated the effect of PM2.5 concentration levels on the atmospheric, weather, environmental, and transportation conditions in a target area, and the variation in concentration levels depending on the type of bus stop.
        4,000원
        10.
        2016.02 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We present the rectifying and nitrogen monoxide (NO) gas sensing properties of an oxide semiconductor heterostructure composed of n-type zinc oxide (ZnO) and p-type copper oxide thin layers. A CuO thin layer was first formed on an indium-tin-oxide-coated glass substrate by sol-gel spin coating method using copper acetate monohydrate and diethanolamine as precursors; then, to form a p-n oxide heterostructure, a ZnO thin layer was spin-coated on the CuO layer using copper zinc dihydrate and diethanolamine. The crystalline structures and microstructures of the heterojunction materials were examined using X-ray diffraction and scanning electron microscopy. The observed current-voltage characteristics of the p-n oxide heterostructure showed a non-linear diode-like rectifying behavior at various temperatures ranging from room temperature to 200 oC. When the spin-coated ZnO/CuO heterojunction was exposed to the acceptor gas NO in dry air, a significant increase in the forward diode current of the p-n junction was observed. It was found that the NO gas response of the ZnO/CuO heterostructure exhibited a maximum value at an operating temperature as low as 100 oC and increased gradually with increasing of the NO gas concentration up to 30 ppm. The experimental results indicate that the spin-coated ZnO/CuO heterojunction structure has significant potential applications for gas sensors and other oxide electronics.
        4,000원
        11.
        2008.09 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study is to analyze the characteristics of hydraulic behavior of the natural channel flow according to the temporal classification mode, and thus propose the hydraulic analysis method for future channel design. For analysis, the temporal flow characteristics of the channel section was divided into the steady flow and the unsteady flow. For hydraulic analysis, the HEC-RAS model, which is a one-dimensional numerical analysis model, and the SMS-RAM2 model, which is a two-dimensional model, were used and the factors used for analysis of hydraulic characteristics were flood elevation and flow rate. The flow state was analyzed on the basis of the one-dimensional steady flow and unsteady flow for review. In the unsteady flow analysis the flow rate changed by (-)0.16%~(+)0.26%, and the flood elevation varied by (-)0.35%~(+)0.51% as compared to the values in the steady flow analysis. Given these results, in the one-dimensional flow analysis based on the unsteady flow the flood elevation and flow rate were greater than when the analysis was done on the basis of the steady flow. The flow state was analyzed on the basis of the two-dimensional steady flow and unsteady flow. In the unsteady flow analysis the flow rate varied by (-)0.16%~(+)1.08%, and the flood elevation changed by (-) 0.24%~(+)0.41% as compared to the values in the steady flow analysis. Given these analysis results, in the two dimensional flow analysis based on the unsteady flow, the flood elevation and flow rate were greater than when the analysis was done on the basis of the steady flow.