검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 229

        101.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The result of the previous work leads to the idea that the inner area of the hyperbolic shell generator should be minimized for the cooling tower with higher first natural frequency. In this study the inner area of the hyperbolic shell generator was graphically established under varying height of the throat and angle of the base lintel. From the graph, several shell geometries were selected and analysed in the aspect of the natural frequency. Three representative towers reinforced differently due to different first natural frequencies were analysed non-linearly and evaluated using a damage indicator based on the change of natural frequencies. The results demonstrated that the damage behaviour of the tower reinforced higher due to a lower first natural frequency was not necessarily advantageous than the others
        4,000원
        102.
        2017.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the seismic performance of solid reinforced concrete columns with triangular reinforcement details using nonlinear seismic analysis. The developed reinforcement details are economically feasible and rational, and facilitate shorter construction periods. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. Solution of the equations of motion is obtained by numerical integration using Hilber-Hughes-Taylor (HHT) algorithm. The proposed numerical method gives a realistic prediction of seismic performance throughout the input ground motions for several column specimens. As a result, developed triangular reinforcement details were designed to be superior to the existing reinforcement details in terms of required performance.
        4,000원
        103.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently damage of structures and loss of life by terrorism are internationally increasing. Among these terror that have a possibility to can happen in korea and that can caused lot of human life loss is the vehicle terror. To prevent the vehicle terror, the anti-ram barriers are needed. But domestic standard about anti-ram barriers are not clear. So, in this study, we will utilize and analyze the vehicle impact to evaluate the efficiency of the domestic bollard and suggest the installation standard of those. In Korea, granite, elastic, steel and stainless bollard are used. The performance of those bollard is not available. Elastic bollard couldn’t stop the vehicle, and the others just could stop the vehicle only at the speed under 10kph. Therefore, set the variable to reinforce, and evaluate the defence efficiency of bollard. As a result, granite and elastic bollard was not suitable for the anti-ram barriers. Performance of steel bollard increased as thickness grew. So steel bollard should must be thicker than 10T. And the concrete compressive strength effected insignificantly on the defence efficiency, so more than 24MPa compressive concrete be used. Performance of stainless bollard increased as thickness grew. So stainless bollard should must be thicker than 13T.
        4,000원
        107.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we analysed the influence of the flow and performance of the generated micro gas turbine with different rotational speeds. CFD analysis was also performed using commercial code called ANSYS CFX 14.5. It adopted the turbine of radial flow type suitable for power generation for small rotating equipment. The number of blades was designed with each radial turbine 8, vane nozzle 14. The boundary layer flow analysis was widely used to the SST model. Mass flow rate of the turbine was 1.45 kg/s. While the rpm varies from 38,000rpm to 48,000rpm under various boundary conditions, the distributions of Mach number and pressure were numerically analyzed for electric power output, turbine isentropic efficiency. We analyze the inlet pressure, outlet temperature, electric power output, turbine isentropic efficiency. It compared maximum and minimum revolution through CFD analysis. Power output of maximum revolution has been increased 18% more than minimum revolution. Isentropic efficiency of maximum revolution has been increased 16.5% more than minimum revolution. Therefore, maximum power output was 332kW, amaximum isentropic efficiency was 33.2%.
        4,000원
        108.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The performance of organic Rankine cycle was numerically investigated to recover heat from the exhaust of a heavy-duty diesel engine. Exhaust flow rates and temperatures are obtained from the simulation of diesel cycle by using GT-Power. The net power outputs of organic Rankine cycle for 9 working fluids were calculated by cycle simulations. The results showed that as for the net power outputs and the pressure of working fluids, R21 and R245fa are suitable as working fluids for ORC in diesel engine.
        4,000원
        109.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        소음공해를 방지하기 위한 방음시설물로서 도로, 철로 및 공항 주변에 설치되는 방음벽은 주로 외부에 설치되어 풍하중에 노출된다. 지속적이고 반복적인 풍하중은 방음벽의 피로를 야기하며 높은 풍속이 발생할 경우 붕괴되는 경우도 흔히 발생하고 있다. 본 논문에서는 반사형, 통풍형 등 방음벽의 유형별로 방음벽에 작용하는 풍하중의 발생 과정과 내풍성능 개선방안에 대해서 전산해석을 수행하였다. 통풍형 방음벽의 경우 수압면적이 감소한 것에 비하여 풍하중은 다소 낮은 6.76%의 감소율이 나타난 원인은 풍하면의 통풍공 주변에 발달한 국부적 부압으로 판단되었다. 추가적인 풍하중 저감을 위하여 박리에 의한 와류의 규모를 개선하기 위한 방안으로 상부에 슬릿을 설치한 결과, 최대 14.67%의 감소효과를 나타내었다. 또한 슬릿의 간격이 250mm일 때 15.41%로 풍하중이 감소율이 상대적으로 우수하였으며, 이는 방음벽 상단과 슬릿에 의한 기류의 상호작용이 와류의 규모와 발달에 영향을 미친 것으로 판단된다.
        4,000원
        110.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Determining of the shape in the process of design for natural draught cooling tower is very important, because the shape of hyperbolic shell is respond sensitively to dynamic behavior of the whole cooling tower against wind load. In engineering practice, the geometric parameters have been determining based on the natural frequency. This study analyses influence of the tower shell geometric parameters on the structural behavior. For three representative models were selected, they were analyzed based on evaluation of damage by means of nonlinear FE-method. As a result, a hyperbolic rotational shell with the small radius overall was the lowest damage index induced by sufficient capacity of the stress redistribution and thus a wind-insensitive structure.
        4,300원
        111.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Unreinforced masonry (URM) buildings are known to be highly vulnerable to seismic loadings. Although significant physical variation may exist for URM buildings that fall into a same structural category, a single set of fragility curves is typically used as a representation of the seismic vulnerability of the URM structures. This study investigates the effect of physical variation of URM structures on their seismic performance level. Variables that describe the physical variation of the structure are defined based on the inventory analysis. Seismic behavior of the structures is then monitored by changing the variables to investigate the effect of each variable. The analysis results show that among the variables considered the seismic performance of URM building depends on the variation of the width, the aspect ratio, and the number of story. The need for further research on the modeling of the connections between the walls and diaphragms and the torsional effect is also addressed.
        4,000원
        112.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        동조액체감쇠기(TLD)는 에너지 소산장치로써 구조물의 동적응답을 제어하기 위해 개발되었다. TLD는 풍하중에 의한 구조물의 응답을 제어에 매우 효과적임을 보여줬다. 그러나 TLD가 설치된 구조물의 지진응답의 제어에 대해서는 충분한 연구가 이뤄지지 않았다. 이 연구의 목적은 TLD가 설치된 구조물에 여러 동조비와 질량비를 대입하여 지진에 대한 TLD의 성능을 도출하는 것이다. 이러한 목적을 위해, 수치해석 연구가 실시되며, 다른 토양 조건 또한 고려되었다. 그 결과 지진하중에 대한 TLD의 성능은 구조물의 고유주기, 감쇠비에 따라 다르게 나타났다. 또한 TLD의 동조비 다르게 나타남을 알 수 있었다.
        4,000원
        113.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Piloti-type building is one of typical vertical atypical buildings. These buildings can fail by weak-story or flexible-story mechanism on the first story. They should be designed by taking into account the special seismic load, but those less than six stories are not required to confirm the seismic performance from structural engineers in Korea. For this reason, small-size pilloti-type RC buildings need to be checked for seismic performance. Based on this background, this study performed nonlinear dynamic analysis using the PERFORM-3D for small-size pilloti-type RC buildings and assessed their seismic performance. Examples are two through four story buildings with and without walls in the first story. The walls and columns in the first story satisfied the target performance in the basic of flexural behavior due to quite a large size and reinforcement. However, wall shear demands exceed shear strength in some buildings. When designed for KBC2009, wall shear strength exceed shear demand in some buildings, but still does not in others. Consequently, wall shear must be carefully checked in both existing and new small-size pilloti-type RC buildings.
        4,000원
        114.
        2016.06 구독 인증기관·개인회원 무료
        최근 서울 도심 지역에 위치한 주요 포장도로에서의 동공발생 문제가 다양한 원인으로 인하여 이전 보다 더 빈번하게 나타나는 것으로 대두되고 있는 실정이다. 이 문제는 포트홀과 싱크홀 수 증가와 포장 도로에서의 다른 문제들을 야기 시킨다. 사실, 포장도로에서의 동공발생을 일으키는 주체적인 원인은 강 우, 강설과 같은 기후 변화와 밀접한 관련이 있다. 이 연구에서는, 한국형도로포장설계법에 기반하여 개 발된 KPRP(Korea Pavement Research Program : 한국형 포장설계프로그램)를 이용하여 동상방지층 의 구조적 성능을 모니터링 하고, 유한요소해석 프로그램 중 하나인 KICTPAVE 프로그램을 이용하여 KPRP프로그램의 신뢰도를 확인하고자 한다. KPRP 프로그램은 한국형 도로포장설계법에 기반을 두고 개발 된 프로그램 이다. 사실. 이전에 사용되어지던 설계 법은 AASHTO Interim Guide Method(1972) 로, 한국형포장설계프로그램의 개발 전 국내에서 가장 보편적으로 사용된 설계법이다. 이 설계법은 주어 진 조건 하에서만 포장 단면을 설계하는 법을 도출해내기 때문에 다양한 조건에서의 설계와 구조적인 개 량이 어렵다는 지적이 나오게 되었다. 이를 보완하기 위하여 국내에서의 주어진 조건에 적합하게 도로 포장의 횡단을 설계하기 위해 개발된 한국형포장설계프로그램이 나오게 되었다. 본 연구에서는, KPRP 와 KICTPAVE를 이용하여 동상방지층의 구조적 성능을 더욱 정밀하게 연구하게 된다. 한국형포장설계프로그램은 설계조건을 반영한 후, 횡단면 조건 설정, 기상조건 반영, 교통량 반영, 포장 재료 물성치 반영 및 동상방지층 설치 여부 판단과정을 거쳐 공용성을 예측하게 된다. 설계조건 반영은 한 국형포장설계프로그램에서 제공하는 기본 DB를 활용하여 횡단 설계를 하였다. 본 연구는 효과적인 공용성 분석을 위하여 세 가지 경우로 나누어서 해석을 실시하였는데, 그 조건들은 아래 표 1에 나온 것과 같다. 표 1은 동상방지층의 구조적 성능을 한국형포장설계프로그램을 이용하여 분석해낸 결과 이다. 표 1을 보면 두께와 상관없이 모든 구조적 성능이 일치하게 되는 결과를 가져와서 KICTPAVE 프로그램을 이용하여 조 건을 5가지로 나누어 유한요소해석을 실시하였다. 각 층(동상방지층-노상토, 보조기층-동상방지층, 기층 -보조기층, 표층-기층, 표층 사이의 노드와 요소)은 5cm간격으로 0cm에서 20cm 까지 다섯 가지 경우의 조건으로 나누어서 해석을 하였다. 그 결과 보조기층과 동상방지층 사이의 변형률은 동상방지층의 두께가 두꺼워질수록 증가되는 현상을 보였다. 하지만, 이와는 반대로 노상토와 동상방지층 사이에서 발 생하는 변형률은 동상방지층의 두께가 두꺼워 질 수록 감소되는 현상을 보였다.
        115.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문에서는 벽체의 형상(평면벽체, 곡면벽체) 및 벽체에 도입된 긴장력이 충돌저항성능에 미치는 영향을 수치해석적 기법을 사용하여 평가하고자 하였다. 벽체의 곡률 및 긴장력 도입률을 변수로 총 12 케이스의 충돌해석을 수행하였으며, 충돌체로는 상용 민항기엔진의 3차원 상세모델을 사용하였다. 충돌저항성능을 평가하기 위해 관입깊이와 벽체 중앙부 후면의 최대 변위를 비교하였다. 긴장력의 도입에 의해 관입깊이는 약 60∼80% 수준으로 감소하는 것으로 나타났으나, 후면 변위는 큰 차이가 나타나지 않았으며, 벽체 형상에 따른 차이는 상대적으로 크지 않은 것으로 나타났다.
        4,000원
        116.
        2016.04 구독 인증기관 무료, 개인회원 유료
        Recently, researches of concrete performance improvement are increased in the advanced countries. Most nano material research is analyzed by experiment. This study performs a numerical analysis used by tensile strength of MWCNT and nano continuum theory, so effect on the performance improvements of nano mortar is analytically confirmed. Preceding researches about experimental result of flexural strength by Chan and Andrawes are comparative verified with result of multi-scale finite element modeling. In addition, parametric studies were conducted to investigate the effect of the ratio of width and the ratio of height on the behavior of proposed finite element modeling by nonlinear finite element analyses.
        3,000원
        117.
        2016.04 구독 인증기관·개인회원 무료
        This study investigates the analytical study for evaluating impact resistance capacity and failure mode of PROTECT (Poly-Resilience-Oriented hybrid TEChnology plaTe) panel. PROTECT panel is a composite panel with two steel plates and nano-composite. In order to perform impact analysis, dynamic properties of steels and nano-composite were determined. Finite element analysis is performed with these properties under the drop-weight impact. From the FEA, different failure modes corresponding to different impact energy is derived.
        118.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Nowadays, cavity phenomena occur increasingly in pavement layers of downtown areas. This leads to an increment in the number of potholes, sinkholes, and other failure on the road. A loss of earth and sand from the pavement plays a key role in the occurrence of cavities, and, hence, a structural-performance evaluation of the pavement is essential. METHODS: The structural performance was evaluated via finite-element analysis using KPRP and KICTPAVE. KPRP was developed in order to formulate a Korean pavement design guide, which is based on a mechanical-empirical pavement design guide (M-EPDG). RESULTS: Installation of the anti-freezing layer yielded a fatigue crack, permanent deformation, and international roughness index (IRI) of 13%, 0.7 cm, and 3.0 m/km, respectively, as determined from the performance analysis conducted via KPRP. These values satisfy the design standards (fatigue crack: 20%, permanent deformation: 1.3 cm, IRI: 3.5 m/km). The results of FEM, using KICTPAVE, are shown in Figures 8~12 and Tables 3~5. CONCLUSIONS: The results of the performance analysis (conducted via KPRP) satisfy the design standards, even if the thickness of the anti-freezing layer is not considered. The corresponding values (i.e., 13%, 0.7 cm, and 3.0 m/km) are obtained for all conditions under which this layer is applied. Furthermore, the stress and strain on the interlayer between the sub-grade and the anti-freezing layer decrease gradually with increasing thickness of the anti-freezing layer. In contrast, the strain on the interlayer between the sub-base and the anti-freezing layer increases gradually with this increase in thickness.
        4,000원
        119.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 NO96 화물창의 BOG(boil off gas), BOR(boil off rate)을 감소시키기 위한 노력으로 단열재료 및 단열층을 변화시켜서 개발된 NO96-GW, NO96-L03의 방열구조에 대해서 BOG, BOR 값을 계산하고 단열성능을 비교․평가하였다. 두 가지의 변형된 NO96 모델을 기존의 NO96 방열과 단열층 및 단열재료의 차이점을 비교하고, 각각의 열저항 및 BOG/BOR 값의 비교 결과를 제시하였다. 열저항 값은 유한요소해석법을 이용하여 계산되었으며, 준정적 열평형 상태를 가정하여 열유속과 온도분포를 통하여 단열성능을 비교하였다. 계산에 사용된 화물창의 모든 재료물성치는 온도 의존값으로서 반영하여 -163oC에서의 극저온 상태에서 특성을 반영되었다. 각 화물창의 BOG, BOR 계산은 국부 열전달 해석을 통해 방열판에서 발생하는 열유속을 계산하고, 등가모델을 적용하여 계산하는 과정으로 수행되었으며, 그 결과를 각 화물창의 단열성능을 비교평가하기 위해서 검토하였다.
        4,000원
        120.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The heat generated by the internal electro-mechanical device is not transferred to the outside, to degrade the performance of the electronic device, or the cause of failure. Heat sinks are used to control the heat. Thermal performance of the heat sink of the pine type and pin type was analyzed using ANSYS software. The numerical results were compared with the thermal performance of the pine type and pin-type heat sink. The results of the numerical simulation showed that Pine type heat sink showed an approximately 58 percent better heat transfer rate with forced convection than Pin type heat sink.
        4,000원