검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The result of the previous work leads to the idea that the inner area of the hyperbolic shell generator should be minimized for the cooling tower with higher first natural frequency. In this study the inner area of the hyperbolic shell generator was graphically established under varying height of the throat and angle of the base lintel. From the graph, several shell geometries were selected and analysed in the aspect of the natural frequency. Three representative towers reinforced differently due to different first natural frequencies were analysed non-linearly and evaluated using a damage indicator based on the change of natural frequencies. The results demonstrated that the damage behaviour of the tower reinforced higher due to a lower first natural frequency was not necessarily advantageous than the others
        4,000원
        2.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Determining of the shape in the process of design for natural draught cooling tower is very important, because the shape of hyperbolic shell is respond sensitively to dynamic behavior of the whole cooling tower against wind load. In engineering practice, the geometric parameters have been determining based on the natural frequency. This study analyses influence of the tower shell geometric parameters on the structural behavior. For three representative models were selected, they were analyzed based on evaluation of damage by means of nonlinear FE-method. As a result, a hyperbolic rotational shell with the small radius overall was the lowest damage index induced by sufficient capacity of the stress redistribution and thus a wind-insensitive structure.
        4,300원
        3.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        하이퍼볼릭 쉘로 구성된 냉각탑에서 쉘의 형상은 풍하중에 대하여 냉각탑 전체의 동적 거동에 민감하게 응답한다. 이에 따라 냉각탑 설계 시 기하형상의 결정은 매우 중요하며 일반적으로 고유진동수를 기반으로 하여 산정한다. 본 연구의 목적은 냉각탑 쉘의 구조적 거동에서 형상변수가 미치는 영향을 파악하고자 한다. 기존의 냉각탑 형상변수를 변화시켜 32개의 모델을 선정하였고 이를 1차 고유진동수를 기반으로 하여 분석한 후, 3개의 대표적인 형상을 선택하여 선형 해석을 수행하였다. 그 결과, 전체적으로 작은 반지름을 가지는 기하형상이 높은 1차 고유진동수를 나타내고 풍하중에 대하여 덜 민감한 시스템이 되는 것을 알 수 있었다.
        4,000원
        4.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        본 연구는 연쇄붕괴 저항성능 평가 시 기둥의 순간적인 제거에 따른 동적효과가 반영된 에너지 기반 근사해석의 적용성을 확인하 기 위해 내진 설계된 철골모멘트골조의 예제구조물을 대상으로 분석하였으며, 이를 통해 구조 강건성을 산정하여 연쇄붕괴에 대한 민감도를 평가할 수 있는 방법을 제시하였다. 예제구조물에 대한 적용을 통해 비선형 정적해석 결과를 이용한 에너지 기반 근사해석과 직접동적해석에 대한 결과가 잘 일치하는 것을 검증하였으며, 다른 구조시스템을 가지는 건물의 연쇄붕괴에 대한 구조적 내력성능을 비교하기 위한 수단으로 구조물의 민감도를 평가하였다. 이는 비정상하중에 대하여 구조물이 연쇄붕괴에 저항할 수 있는 최대보유 잔류내력 성능인 구조 강건성을 이 용하였고, 본 연구에서 제시한 방법을 통해 연쇄붕괴 해석 및 설계에 편리하게 활용될 수 있음을 확인하였다.
        5.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        A new precast concrete (PC) beam and column connection system using non-prestressed wire strands was recently developed. The system is composed of one unit of two-storied PC-column and PC-beams with U-shaped ends. The connection part of the column and beams is reinforced by deformed bars and non-prestressed wire strands in combination for the improvement of workability. Structural performance of this system was verified by several experimental studies. The purpose of this study is developing a design concept of the beam reinforced by deformed bars and non-prestressed wire strands in combination, in terms of the cross-sectional analysis, based on the preceded experiment. A minimum and maximum reinforcement ratio and the calculation formula for the strength of flexural member reinforced by reinforcements having different yield strengths are derived based on KBC2009. Under consideration existing research results for the application of high strength reinforcement bars, the design yield strength of the non-prestressed wire strand is suggested. An example for the cross section design, satisfying the serviceability requirements, demonstrates the applicability of the design concept developed in the study.
        6.
        2012.05 서비스 종료(열람 제한)
        The shell of form-finding is most important in design procedure of the cooling tower, because the shape of the shell determines the sensitivity of dynamic behavior of the whole tower against wind excitation. The purpose of the study is the investigation of the influences of the geometric parameters of the cooling tower shell on the structural behavior. As a result, a hyperbolic rotational shell with the small radius overall will yield the shell geometry with a higher first natural frequency and thus a wind-insensitive structure. Linearly and nonlinearly numerical analysis are demonstrated influence of the shell-geometric parameters on structural behaviours. The results of this study may be informative for the form-finding of the cooling tower shell.
        7.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 국내 콘크리트구조설계기준 부록에 새롭게 포함된 CEB-FIP Model Code 1990 균열폭 산정식을 콘크리트 강도를 변수로 하여 평가하는 것에 있다, 평가 도구로 부착응력-미끌림 관계를 적용하여 구축한 균열요소모델과 기존 연구자들의 실험결과로부터 얻은 균열폭을 사용하였으며 기존 실험결과와 비교 평가함으로 검증하였다. 평가대상인 MC-90의 균열폭 산정식의 증요변수는 인장증강효과와 평균부착응력이며 이들을 균열요소모델 해석결과와 비교함으로 강도에 따라 개선된 인장증강효과와 평균부착응력을 제안하였다.
        8.
        2007.09 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 원형강관 가새의 국부좌굴에 의한 내력감소를 배제하기 위하여, 가새의 국부좌굴 거동을 파악하고 좌굴제어 방법을 찾고자 한다. 좌굴을 제어하기 위한 방법으로, 하나는 좌굴 영역에 커버플레이트를 설치하여 좌굴을 구속함으로써 변형능력을 확보하고자 하는 것이며, 다른 하나는 가새 중앙부에 강봉과 스프링을 이용한 수축장치를 삽입하여 압축 시 좌굴의 위험을 배제하는 것이다. 본 연구의 목적은 국부좌굴을 구속하거나 배제하기 위한 좌굴제어시스템을 제안하고, 실험을 통하여 제안한 방법의 적용성을 조사, 검토하는 것이다. 또한 좌굴제어에 따른 성능향상을 정량적으로 평가하는 것이다.