        검색결과 235

        41.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, an experimental study was carried out for vibration control of cable bridges with structurally flexible characteristics. For the experiment on vibration control, a model bridge was constructed by reducing the Seohae Grand Bridge and the shear type MR damper was designed using the wind load response measured at Seohae Grand Bridge. The shear type MR damper was installed in the vertical direction at the middle span of the model bridge, and dynamic modeling was performed using the power model. The tests of the vibration control were carried out by non-control, passive on/off control and Lyapunov control method on model bridge with scaled wind load response. The performance of the vibration control was evaluated by calculating absolute maximum displacement, RMS displacement, absolute maximum acceleration, RMS acceleration, and size of applied power using the response (displacement, acceleration, etc.) from the model bridge. As a result, the power model was effective in simulating the nonlinear behavior of the MR damper, and the Lyapunov control method using the MR damper was able to control the vibration of the structure and reduce the size of the power supply.
        4,300원
        42.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 진동에너지를 흡수하기 위한 진동 금속 댐퍼의 구조 해석과 최적 설계를 수행한다. 고무 베어링, 마찰 또는 점성 댐퍼와 같은 다른 댐퍼와는 달리 이 금속제진장는 금속의 소성 변형과 그에 따른 히스테리시스 현상을 이용하여 구조물의 진동을 감소시킨다. 이 금속제진장치를 최적화 하려면 댐퍼를 통해 소성 변형을 얻는 것이 중요하다. 금속제진장치의 최적화 된 형상을 찾기 위해 형상 최적화 방법을 적용하였다. 또한 매개 변수화 체계에 따라 일부 최적의 모양을 찾을 수 있다.
        4,000원
        43.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents a vibration mitigation method for a railroad station using dual layer TMD (Tuned Mass Damper) technology. The proposed technology can be applied to a platform by installing a spring-damper system between the platform and the railroad station structure. Especially, considering passenger comfort, the technology is developed for not just reducing the vibration of the railroad station structure but minimizing the vibration of the platform. The technology consists of two serially connected masses, and the vibration of the top mass is designed to be minimized, while the bottom mass serves as the platform TMD. The design parameters such as the spring constant and damping coefficient of the dual layer TMD system are optimized using the acceleration response of the structure, at which the platform is installed. The feasibility and performance of the vibration mitigation method is verified via a numerical example of a simple beam structure subjected to a moving load, which can be analogized as a railroad station with a moving train on top. The result of the numerical study shows that the proposed method can effectively reduces the vibration of the top mass as well as the beam structure at the design speed of the moving load.
        4,000원
        44.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The demand for skyscrapers is increasing worldwide. Until now, various lateral resistance structures have been used for lateral displacement control of high-rise buildings. An outrigger damper system has been introduced recently to improve lateral dynamic response control performance further. However, a study of outrigger damper system is yet to be sufficiently investigated. In this study, time history analysis was performed to investigate the control performance of an outrigger damper system of high-rise building under eccentric loading. To do this, an actual scale 3-dimensional tall building model with an outrigger damper system was prepared. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. On the top floor torsional angle response to the earthquake load, was greatly affected by damping value. And the displacement response was affected greatly by the stiffness value and damping value of damper system. In conclusion, it is necessary to select the proper damping and stiffness values of the outrigger damper system.
        4,000원
        45.
        2017.04 구독 인증기관 무료, 개인회원 유료
        This study began the studies to develop a general-purpose expression furniture flap damper module set to prevent that noise and caught in through as a result, to obtain the following results using the same study procedure. First, to develop a damper bracket and hardware. Second, we want to create the design drawings for the furniture flap type damper module three. Third, we want to create a mock-up sample and mold in progress. Fourth, the tester will be designed and manufactured to produce a universal formula Furniture flap dampers module. Fifth, to conduct a test for the successful production of furniture damper module set. Study the sixth oil impregnation technology and to develop a general-purpose expression furniture damper flap. Finally, the set of all of the modules are to the development of molds followed successfully.
        4,000원
        46.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The boundary reaction method(BRM) is a substructure time domain method, it removes global iterations between frequency and time domain analyses commonly required in the hybrid approaches, so that it operates as a two-step uncoupled method. The BRM offers a two-step method as follows: (1) the calculation of boundary reaction forces in the frequency domain on an interface of linear and nonlinear regions, (2) solving the wave radiation problem subjected to the boundary reaction forces in the time domain. In the time domain analysis, the near-field soil is modeled to simulate the wave radiation problem. This paper evaluates the performance of the BRM according to modeling extent of near-field soil for the nonlinear SSI analysis of base-isolated NPP structure. For this purpose, parametric studies are performed using equivalent linear SSI problems. The accuracy of the BRM solution is evaluated by comparing the BRM solution with that of conventional SSI seismic technique. The numerical results show that the soil condition affects the modeling range of near-field soil for the BRM analysis as well as the size of the basemat. Finally, the BRM is applied for the nonlinear SSI analysis of a base-isolated NPP structure to demonstrate the accuracy and effectiveness of the method.
        4,600원
        47.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 풍하중을 받는 건물에 설치된 다중거동 복합 감쇠장치(MHD)의 성능을 평가하고, MHD 예비설계 절차를 제안하였다. MHD에 의해 증가된 등가감쇠비와 그에 따른 건축구조기준에 근거한 응답저감계수를 예상한 후, 풍하중 스펙트럼에 의해 생성된 풍하중을 사용하여 20층 철골구조물에 대한 시간이력 해석을 수행하였다. 해석결과를 통해 얻어진 층변위 및 층간변위 평균 응답 감소율은 각각 0.585 및 0.525로, 이는 제안한 예비설계과정에서 추정된 응답감소계수 0.6과 거의 동일한 수치임을 확인하였다. 이로부터 제안된 방법을 사용하여 MHD의 제어효과를 효과적으로 평가할 수 있음을 확인하였다.
        4,000원
        48.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, an outrigger damper system has been proposed to reduce dynamic responses of tall buildings. However, a study on outrigger damper system is still in its early stages. In this study, time history analysis was performed to investigate the dynamic response control performance of outrigger damper. To do this, a actual scale 3-dimensional tall building model with outrigger damper system has been developed. El Centro earthquake was applied as an earthquake excitation. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. Analysis results, on the top floor displacement response to the earthquake load, was greatly effected by damping value. And acceleration response greatly was effected by stiffness value of damper system. Therefore, it is necessary to select that proper stiffness and damping values of the outrigger damper system.
        4,000원
        49.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The proposed hybrid damper installs at a coupling beam and consists of a high-damping rubber (HDR) and steel pin. The proposed hybrid damper adopted a pin-lock system acts as a viscoelastic damper under wind load (small displacement) while it behaves as a hysteretic damper under earthquake load (large displacement). In this paper, the pin-lock mechanism and structural performance of the proposed hybrid damper is evaluated through experiment. Experiments were carried out with the variables which displacement, loading frequency and steel pin quantities were used. Test results showed that the pin-lock mechanism and the performance of the hybrid damper under a large displacement were verified. Also equivalent damping ratios of HDR were increasing at a small displacement as displacement amplitudes were increasing. However HDR did not depend on frequency,
        4,000원
        50.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An outrigger damper system has been proposed to reduce dynamic responses of tall buildings. In previous studies, an outrigger damper system was optimally designed to decrease a wind-induced or earthquake-induced dynamic response. When an outrigger damper system is optimally designed for wind excitation, its control performance for seismic excitation deteriorates. Therefore, a smart outrigger damper system is proposed in this study to make a control system that can simultaneously reduce both wind and seismic responses. A smart outrigger system is made up of MR (Magnetorheological) dampers. A fuzzy logic control algorithm (FLC) was used to generate command voltages sent for smart outrigger damper system and the FLC was optimized by genetic algorithm. This study shows that the smart outrigger system can provide good control performance for reduction of both wind and earthquake responses compared to the general outrigger system.
        4,000원
        51.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, Stockbridge damper was adopted to reduce the reponses of structures under earthquakes. A finite element analysis software, SAP2000, was used to simulate the structural response and the control device under dynamic loads. A 3 story frame model and the proposed control device, Stockbridge damper, were designed under laboratory conditions. In this research, a pendulum type tuned mass damper (PTMD) was also adopted in order to compare with the Stockbridge damper. Harmonic loads were applied to verity the control performance of both control devices in each mode. In results, it has been found that the Stockbirdge damper decreases significantly the responses of the structure more than the PTMD under the harmonic loadings. The El Centro and Northridge earthquakes were also applied in order to investigate the performance by both control devices. The responses of the building demonstrate that the Stockbridge damper reduces the response of the building structure during earthquakes more effectively than the PTMD.
        4,000원
        52.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new design concept for integrated thermal energy storage system is suggested to increase energy saving rate for heating and cooling system of the closed glass greenhouse. Heat pump of air source is installed in the mechanical room and air flows then controlled by damper system located between the greenhouse and outdoor environments. A damper control algorithm is designed to enhance the usage of excessive energy in the glass greenhouse. Since the proposed system is installed at the actual glass greenhouse site for experimental verification of energy savings, the proposed system with damper control is compared with conventional greenhouse heating and cooling system. From results, it is found that more than 10% increase of energy saving rate is achieved.
        4,000원
        53.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        동조액체감쇠기(TLD)는 에너지 소산장치로써 구조물의 동적응답을 제어하기 위해 개발되었다. TLD는 풍하중에 의한 구조물의 응답을 제어에 매우 효과적임을 보여줬다. 그러나 TLD가 설치된 구조물의 지진응답의 제어에 대해서는 충분한 연구가 이뤄지지 않았다. 이 연구의 목적은 TLD가 설치된 구조물에 여러 동조비와 질량비를 대입하여 지진에 대한 TLD의 성능을 도출하는 것이다. 이러한 목적을 위해, 수치해석 연구가 실시되며, 다른 토양 조건 또한 고려되었다. 그 결과 지진하중에 대한 TLD의 성능은 구조물의 고유주기, 감쇠비에 따라 다르게 나타났다. 또한 TLD의 동조비 다르게 나타남을 알 수 있었다.
        4,000원
        54.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the case where a MR-damper is employed for vibration control, it is important to decide on how much control capacity should be assigned to it against structural capacities (strength and load, etc). This paper aims to present a MR-damper's control capacity suitable for the capacities of the structure which needs to be controlled. First, a two span bridge was built equipped with a MR-damper, which constitutes a two-span MR-damper control system. Then, inflicting an earthquake load on the system, a basic experiment was performed for vibration control, and a simulation was also carried out reflecting specific control conditions such as MR-damper and rubber bearing. The comparison of the results against each other proved their validity. Then, in order to calculate an optimal control capacity of the MR-damper, structural capacity was divided into eleven cases in total and simulated. For each case, an additional load of 30 KN was inflicted everytime, thereby increasingly strengthening structural capacity. As a result of the study, it was found that the control capacity of MR-damper of 30 KN was safely secured only with lumped mass of more than 150 KN(case 6). Therefore, it is concluded the MR-damper showed the best performance of control when it exerted its capacity at around 20% of structural capacity.
        4,000원
        55.
        2016.04 구독 인증기관·개인회원 무료
        This study investigates the analytical study for developing PEB(Pre-Engineered Building) connection Steel damper. The state-of the art of the steel beam-column seismic connection details were studied previously to develop proper damper for PEB connection. Finite element analysis is performed to develop the prototypes of damper under cyclic load. The study parameters of analysis are the shape, length, thickness, orientation and location of damper. As a result of finite element analysis, three prototype damper details for PEB seismic connection are derived. One is tapered plate on the lower flange of the rafter, another is C-plate on the center of panel zone and the other is brace on the beam-column connection.
        56.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is concerned with an experimental research to control of random vibration caused by external loads specially in cable-stayed bridges which tend to be structurally flexible. For the vibration control, we produced a model structure modelled on Seohae Grand Bridge, and we designed a shear type MR damper. On the center of its middle span, we placed a shear type MR damper which was to control its vibration and also acquire its structural responses such as displacement and acceleration at the same site. The experiments concerning controlling vibration were performed according to a variety of theories including un-control, passive on/off control, and clipped-optimal control. Its control performance was evaluated in terms of the absolute maximum displacements, RMS displacements, the absolute maximum accelerations, RMS accelerations, and the total power required to control the bridge which differ from each different experiment method. Among all the methods applied in this paper, clipped-optimal control method turned out to be the most effective to reduces of displacements, accelerations, and external power. Finally, It is proven that the clipped-optimal control method was effective and useful in the vibration control employing a semi-active devices such MR damper.
        4,200원
        57.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the concept of damped outrigger system has been proposed for tall buildings. But, structural characteristics and design method of this system were not sufficiently investigated to date. In this study, the dynamic response control performance of outrigger damper has been analyzed. To this end, a simplified analysis model with outrigger damper system has been developed. Use the El Centro seismic(1940, NS) analysis was performed. Analysis results, on the top floor displacement response to the earthquake response, did not have a big effect. However, acceleration response control effect was found to be excellent. The increase of outrigger damper capacity usually results in the improved control performance. However, it is necessary to select that proper stiffness and damping values of the outrigger damper system because, the outrigger damper having large capacity is result in heavy financial burden.
        4,000원
        58.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Damped outrigger systems have been proposed as a novel energy dissipation system to protect tall buildings from severe earthquakes and strong wind loads. In this study, semi-active damping devices such as magnetorheological (MR) dampers instead of passive dampers are installed vertically between the outrigger and perimeter columns to achieve large and adaptable energy dissipation. Control performance of semi-active outrigger damper system mainly depends on the control algorithm. Fuzzy logic control algorithm was used to generate command voltage sent to MR damper. Genetic algorithm was used to optimize the fuzzy logic controller. An artificial earthquake load was generated for numerical simulation. A simplified numerical model of damped outrigger system was developed. Based on numerical analyses, it has been shown that the semi-active damped outrigger system can effectively reduce both displacement and acceleration responses of the tall building in comparison with a passive outrigger damper system.
        4,000원
        59.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The new rotary friction damper was developed using several two-nodal rotary frictional components with different clamping forces. Because of these components, the rotary friction damper can be activated by building movements due to lateral forces such as a wind and earthquake. In this paper, various dependency tests such as displacement amplitude, forcing frequency and long term cyclic loading were carried out to evaluate on the structural performance and the multi-slip mechanism of the new damper. Test results show that the multi-slip mechanism is verified and friction coefficients are dependent on displacement amplitute and forcing frequency except long term cyclic loading.
        4,000원
        60.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various hybrid dampers have been developed as increasing tall buildings in Korea. To minimize the installment space and cost, the new hybrid friction damper was developed using friction components. It is composed of two one-nodal rotary frictional components and a slotted bolted frictional connection. Because of these components, hybrid friction damper can be activated by building movements due to lateral forces such as a wind and earthquake. In this paper, displacement amplitude dependency tests were carried out to evaluate on the structural performance and the multi-slip mechanism of the hybrid damper. Test results show that the multi-slip mechanism is verified and friction coefficients are increasing as displacement amplitudes are increasing.
        4,000원