검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 10

        1.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a survey on students’ perceptions of air pollution, particulate matter (PM) and indoor air quality (IAQ) in school classrooms was analyzed. A total of 174 students participated in the survey, where 127 and 47 participants were elementary school students and middle school students, respectively. The elementary school was located in a rural area of Korea, whereas the middle school was located in an urban area. The questionnaire of the survey was mainly composed of three parts: (1) students’ perceptions of air pollution, (2) students’ perceptions of IAQ in the classroom, and (3) students’ perceptions of how to improve IAQ in the classroom. Based on our study, the responses of the students for the given questionnaire showed an opposite tendency. The students in the rural area tended to have positive perceptions regarding IAQ in the classroom as well as air pollution, whereas the students in the urban area revealed negative perceptions for the same items. Our survey results can be used by school officials in order to maintain and improve IAQ in school classrooms based on the perceptions of the students.
        4,000원
        2.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The urban expressway is widely used to avoid traffic jams in highly-populated urban areas. However, vehicle exhaust can be easily transported to the neighboring area including residential buildings. In this study, we investigated the transport and penetration of vehicle exhaust into the nearby high-story residential building. Black carbon (BC) and lung deposited surface area (LDSA) concentrations were monitored every 1 min using an aethalometer (AE51, Magee) and a nanoparticle aerosol monitor (AeroTrak 9000, TSI), respectively. For comparison, the measurement was carried out in both the living room and balcony of the apartment from January 18 to January 25, 2016. The CO2 concentration indicated the presence of residents in the living room and transport of vehicle exhaust from the roadway in the balcony. Its diurnal variation showed a significant difference between weekdays and the weekend, implying the different time activity of residents and traffic volume. BC and LDSA concentrations were 1.4±1.5 μg/m3 and 53.9±45.0 μm2/cm3 indoors, and 1.9±1.0 μg/m3, 76.2±34.5 μm2/cm3 outdoors, respectively. The indoor to outdoor concentration ratios range from 0.6 to 0.8, indicating the significant influence of outdoor vehicle exhaust. The highest concentrations of BC and LDSA were observed in the morning rush hours, except for those indoors during the weekend. In particular, the outdoor effect is significant during the morning rush hours. Indoor air quality management is urgently needed for residents living near the urban expressway.
        4,000원
        3.
        2010.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        To research indoor air pollution in the training rooms of technical high school, the temperature, air current, humidity, CO2, CO, O3 were measured by Indoor Climate System(ICS 500, Casella, UK) at each classroom, scientific laboratory, electricity training room, electronic equipment training room and welding training room. The change of air pollution concentration and its correlation were additionally compared and analyzed. At closed small space such as classroom, scientific laboratory, electronic equipment training room and electricity training room, the CO2 concentration was obtained to the 2,030ppm(max.), which is higher than notified and recommended standard value(1,000ppm) by Ministry of Health and Welfare and Ministry of Environment, Korea. At welding training room where is larger and more ventilated than general classroom, CO concentration was measured to the 3.6ppm, which is higher than average 1ppm measured at other training rooms. The concentration of O3 is not yet regulated from the standards of underground air quality, but at welding training room it was measured as 0.11ppm(max.) that is higher than 0.01ppm measured at other training rooms. The higher value of temperature, air current, radiant temperature and CO2 concentration was shown at scientific laboratory, electricity training room and electronic equipment training room where are closed and same with the scale of classroom. And the higher concentration of CO2, CO and O3 was shown at welding training room which was opened larger classroom. The indoor air pollution by CO2, CO and O3 may directly affect on the training room where many students work at a small space, and they should be controlled appropriately. Each experimental formulas were made for the estimation of CO2, CO and O3 concentration depending on some kinds of variables at each training room. It is found that indirect ventilation system with a filter will be needed for regular and constant ventilation and the ventilation system should be applied to protect and make clean and comfortable environment of training rooms at technical high school.
        4,600원
        4.
        2008.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was performed to investigate airborne volatile organic compounds(VOCs), formaldehyde, respiratory particulate for concentration in primary schools. The concentrations of major indoor air pollutants(VOCs , benzene, toluene, ethylbenzene, xylene, styrene, formaldehyde, PM-10) were observed from November to December 2006. Sampling was undertaken at 81 primary schools. The sampling sites of air pollutants are classroom and hallway. VOCs with distribution of most of general environmental contamination material will be able to confirm that it shows the log-normal distribution which is similar exposure distribution. The exposure quality of VOCs and the place pollution level was indoor> hallway>outdoor, which whole is located in the metropolis and the industrial areas is higher than farm village area. It tried to observe the I/O ratio, it appeared highly from the interior of the material of most. The mean concentrations of formaldehyde, respiratory particulate were 22.07㎍/㎥, 88.06㎍/㎥ respectively. Indoor and outdoor ratios(I/O) of formaldehyde and respiratory particulate were 3.6 and 1.4, respectively. The concentration of respiratory particulate is 27.2% higher than guideline for school hygiene(100㎍/㎥). From the comparison in the construction year, the highest concentration of formaldehyde is showed under one year. However, as time passed by the concentrations of formaldehyde become lower.
        4,500원
        6.
        2007.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was to investigate distribution characteristics for air pollutants and to assess probability of health effect for children in kindergartens from August, 2006 to January, 2007. The mean concentrations for standards of maintenance in kindergartens were 91.5 ㎍/㎥ for PM10, 1,185 ppm for CO2, 69.3㎍/㎥ for formaldehyde, 174 CFU/㎥ for TBC and 0.41 ppm for CO, respectively. For NO2, Rn, TVOC, and O3, the mean concentrations in kindergartens were 29.40 ppb, 1.51 pCi/ℓ, 257.3 ㎍/㎥, and 3.74 ppb, respectively. The I/O ratio of every air pollutants exceeded "1" except for O3. In results of calculated safety factor to assess probability of health effect for children by air pollutants in kindergartens, safety factor for CO2 was 1.2 for fixed point. It means that children have probability of health effect caused by CO2. In cases of Monte-Carlo analysis, safety factor for PM10 was 1.0 and safety factor for CO2 was 1.2.
        4,000원
        7.
        2006.02 구독 인증기관 무료, 개인회원 유료
        In this study, the paint, which has very close relationship to the of indoor air quality, was examined for the air pollution leveling test, and using the various passive sampler, the test was evaluated on the regard of TWA(Time Weighted Average). This study is to examine how the air pollution levels differ between the regular paint that is used for public and the new developed environment friendly paint. The consecutive experiments were performed in the small chamber test to investigate the VOCs and formaldehyde, ammonia emissions and characteristics from paint which are commonly used as the complete material of building. In conclustion, the natural paint showed the highest emission of VOCs among the selected paints, and water paint showed the highest contents of ammonia. Formaldehyde showed N.D(Not Detected) in most of tests and found a small amount in vinyl paint however, it was not as bad as to fail the certify level of building materials. It is recommended to constantly develop the chamber system and it will be very much possible to be used for the estimation of indoor air pollutants from the various paints and other complete materials.
        4,800원
        8.
        2004.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        We gathered exposure data on indoor air pollution, and investigated the dose-response slope factor for indoor air pollutants, such as volatile organic compounds, aldehydes and radon. Population cancer risks (that is the theoretical cancer deaths) were estimated from exposure to the pollutants. In addition, the damage costs, due to their risks, were estimated using WTP (willingness to pay) and VSL (value of a statistical life), which were investigated by a dichotomous contingent valuation method (DCVM). As a priority for human health risks and damage costs, management strategies are required for both radon and formaldehyde as indoor air pollutants. When the numeric results of human risks and damage costs are applied for other purposes, some assumptions and uncertainties have to be considered to use the results as useful screening tools for the administration of practical risk-based priorities.
        4,600원
        9.
        2008.12 KCI 등재 서비스 종료(열람 제한)
        신축공동주택에서는 BAKE OUT등의 입주 전(前) 전처리후 저 농도의 잔여 오염원의 제거를 위해서는 단시간에 고효율의 공기정화기능에 맞춰진 기계적 장치보다는 설치 및 유지, 운영비가 저렴하고 비교적 안전한 생물학적 처리법이 더 효율적이므로 생물학적 실내공기정화 기술의 개발이 시급한 실정이다. 이를 위해 본연구는 실내공기자연정화효과가 있는 식물에 의한 biofilter의 개발을 목표로 하였으며, biofilter hardware의 안전하고 지속적인 기능성 향상을 위해 토양별 공기유동과 수분유지력을 실험을 하였다. 식물에 의한 biofilter는 공기유동과 함께 오염원이 필터내로 유입되어 생물학적 오염 정화 기능으로 인해 정화된 공기가 배출되는 원리이다. 그러나 식물에 의한 biofilters는 공기유동이 높아지면 수분유지력이 낮아지는 특성이 있어 공기유동과 수분유지의 최적 조건을 찾는것이 중요하다. 또한 공기유동과 수분유지에 영향을 미치는 요인은 biofilter내 토양은 공기유동, 수분유지력은 biofilter의 성능과 안정성을 결정짓는 가장 중요한 요인이라 할수 있다. 실험결과, 기기내 공기유동은 3번째 모델에서 공기의 유입과 출입이 가장 최적이며, 토양구성은 vermiculite/ perlite/ peatmoss=v/v/v=0.25/0.25/0.50으로 구성된 토양에서 가장 효율적을 알수 있었다. 이때, 재관수시점은 토양수분의 60%를 관수시점으로 산정하였을 경우 4th-model은 24시간, 3rd-model은 24시간, 2nd-model은 18시간, 1st-model은 18시간, control은24시간으로 나타났다. 그러므로 본연구에서 개발된 biofilter는 공기유동 과 수분을 장시간 유지할수 있으므로 공기유동시 biofilter내 여러 자연 필터와 함께 식물이 실내오염원을 정화할수 있는 유용한 장치가 될 수 있다고 하겠다.