검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 54

        41.
        2015.10 서비스 종료(열람 제한)
        Flexural behavior of precast concrete sandwich wall panels (PCSW) can be divided into one way or two-way according to their aspect ratio. A total of five specimens were tested to find out the effects of design direction of shear connectors and the type of insulation on flexural behavior of PCSW. Design of shear connector in two-way direction has better performance in terms of initial stiffness than those of design of shear connector in one-way direction. Also, the specimens with extruded polystyrene (XPS) foam has higher performance in terms of initial stiffness and ultimate strength than those of the specimens with for expanded polystyrene (EPS) foam.
        42.
        2014.04 서비스 종료(열람 제한)
        Typically low-rise dormitory designed bearing wall system. So, insulated concrete sandwich panel for the application of a rigid frame structure was changed. This study presents field application of insulated concrete sandwich panel through applying Test-Bed.
        43.
        2014.02 서비스 종료(열람 제한)
        샌드위치패널은 시공상의 용이함과 비용대비 높은 단열효과를 가지는 장점으로 공장 및 창고등 많은 분야에서 시공이 이루어지고 있다. 하지만 지난 안성 냉동창고 화재사고에서 볼 수 있는 가연성 패널이 가지는 화재확산 위험성이 상존하고 있어 대형 화재사고의 주범으로 지목되고 있으며, 소방활동을 하는 일선 소방관들에게 큰 위해 요인으로 작용하고 있다. 본 연구에서는 이러한 샌드위치패널의 화재위험성을 평가하기 위하여 가연성 패널과 글라스울 패널의 비교실험을 실시 하였다. 실험을 위하여 ISO 9705에서 제시된 구획실을 구성하였으며 내부에는 목재크립을 적재하여 화재를 모사하였다. 실험결과 가연성 패널의 경우 화재발생 후 약 2분후에 플래쉬오버가 발생하여 붕괴가 진행되었으며, 내부 최대온도는 976℃로 고온으로 측정되었다. 따라서 현재의 시편크기의 시험에서는 평가하기 어려운 구조적 안정성등 종합적인 화재 안전 평가를 위한 실규모의 화재 성능 평가법(KS F ISO 9705등)의 도입이 적극 검토되어야 할 것으로 평가된다.
        44.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        This paper describes an experimental program to investigate the shear behavior of insulated concrete sandwich panels (CSPs) with different types of GFRP shear connector. The study included testing of 13 insulated CSP specimens with two types of surface conditions for extruded polystyrene (XPS) insulation and various shapes of shear connectors. All specimens were loaded in direct shear by means of push-out and were consist of three concrete panels, two insulation layer and four rows of GFRP shear connectors. Load-relative slip between concrete panel and insulation response of CSP specimens has been established through push-out shear test. Test results indicate that the surface condition of insulation has a significant effect on the bond strength between concrete panel and insulation. The specimen used XPS foam with 10mm deep slot shows higher bond strength than those used XPS foam with meshed surface. Corrugated GFRP shear connectors show equivalent strength to grid GFRP shear connectors. Cross-sectional area and embedded length of shear connector have a notable effect on overall response and inplane shear strength of the CSP specimens.
        45.
        2012.11 서비스 종료(열람 제한)
        This study is to evaluate performance of two-way acting insulated sandwich wall panels through flexural experiment. The two-way acting panel resists wind loading on the panel and on the window. In this study, GFRP(Glass Fiber-Reinforced Polymer) Grid-type shear connectors are used for the composite action of the sandwich wall panels. Layouts of shear connector are considered as main parameter of this experimental study.
        46.
        2012.11 서비스 종료(열람 제한)
        This study is to evaluate fatigue resisting capacity of insulated sandwich wall panel under wind-induced fatigue loading. The fatigue loading is calculated based on the probability distribution function (Weilbull and Rayleigh). The serviceability of the insulated sandwich panel was evaluated subjected to the probability-based fatigue loading.
        47.
        2012.11 서비스 종료(열람 제한)
        This study presents bond performance of insulated concrete sandwich panel systems considering different type of insulation through two-way acting insulated concret sandwich panel mock-up test under wind pressure.
        48.
        2012.05 서비스 종료(열람 제한)
        This paper describes the structural behavior of insulated concrete wall panels with no-bond stress insulation. That panels reinforced with fiber reinforced polymer (FRP) truss shear connector to achieve composite action of inner and outer concrete wythes. Main test variable is bond stress. According to the test result, the shear capacity of increased due to bond stress and reinforced with FRP truss shear connector.
        49.
        2012.05 서비스 종료(열람 제한)
        This paper describes the structural behavior of insulated concrete wall panels with EPS insulation. That panels reinforced with Fiber Reinforced Polymer (FRP) truss shear connector to achieve composite action of inner and outer concrete wythes. Main test variables are FRP cross section, width and picth. According to the test result, the shear capacity of increased due to reinforced with FRP truss shear connector. And width 12, 18 mm shear connector need more than 30 mm experiments about reclamation deep.
        50.
        2012.05 서비스 종료(열람 제한)
        This study was shear strength of insulated concrete sandwich panels with tress shear connector. Specimens with results XPSSTG insulation than the EPS insulation was good in the Shear Strength. The maximum displacement is better than the EPS specimens and that of the specimens XPSSTG trends that appear are considered.
        51.
        2011.02 서비스 종료(열람 제한)
        건축물의 단열은 효율적인 에너지 사용을 위한 필수적인 기술이다. 중단열 콘크리트 외벽 시스템은 내/외측에 두 개의 콘크리트 벽체와 중앙부 단열재로 구성되어, 단열성능과 구조성능을 동시에 만족시킬 수 있는 시스템이다. 중단열 콘크리트 외벽 시스템을 구조체에 적용하기 위해서는 콘크리트와 단열재 부착면의 전단내력에 대한 검증이 필연적으로 요구된다. 본 연구는 파형 FRP 전단연결재로 보강한 중단열 콘크리트 외벽 시스템의 전단연결재의 매립깊이, Pitch, 폭에 따른 전단내력을 평가하기 위하여 실시되었다. 실험결과 동일단면적에서 Pitch가 넓은 경우 전단내력이 소폭으로 증가하는 결과를 보였다. 매립깊이가 깊을수록 전단내력을 증가하였고, 폭 12mm 와 18mm의 경우 각 각 35, 40mm 이상의 매립깊이가 필요할 것으로 판단된다.
        52.
        2010.05 KCI 등재 서비스 종료(열람 제한)
        구조물의 해석, 설계, 시공, 품질관리 등을 수립할 때 토목기술자는 경제적이며 효율적인 복합재료를 사용할 수 있다. 거더, 가로보, 콘크리트 상판으로 이루어진 교량시스템은 특별직교이방성 판으로 거동한다. 이러한 경계조건을 갖는 단면을 Navier 해 형태의 해석적 해를 구하기가 매우 어렵다. 복합재료로 이루어진 교량을 설계하기위하여, 단면은 가장 경제적이면서 응력에 유리한 폼코어 형태를 채택하였고, 응력을 산출함에 있어서는 유한차분법 프로그램을 사용하였다. 응력영역은 Tasi-Wu 파괴영역 기준을 이용하였다. 본 논문에서는 치수가 증가됨에 따른 인장강도 감소율을 고려하였다. 또한 이러한 경우에 대한 수치해석을 수행하였다.
        53.
        2007.01 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 복합재료로 만들어진 단순지지된 샌드위치 슬래브 교량의 설계 방법을 제시하고자 한다. 거더나 가로보를 포함한 대부분의 교량시스템에서 교량 상판은 특별직교이방성판으로 거동한다. 이러한 단면을 갖는 시스템은 Navier 해법이나 Levy 해법 형태와는 다른 경계조건 또는 불규칙한 단면을 갖게 되어 해석적 해법을 얻기가 쉽지 않다. 이러한 문제를 해석하기 위하여 유한차분법이 이용되었다. 복합재료로 이루어진 교량을 설계하기위하여, 단면은 가장 경제적이면서 응력에 유리한 폼코어 형태를 채택하였고, 응력을 산출함에 있어서는 유한차분법 프로그램을 이용하였다. 복합신소재 특수기술자의 실험을 기초로 질량이 증가에 따른 파이버의 인장강도 감소를 나타내는 공식을 도출하였다. 이 공식으로부터 치수 증가에 따른 인장강도 감소량을 구 할 수 있다. 파괴강도는 Tasi-Wu의 파괴강도이론을 이용하였다. 파괴강도해석은 본 논문에서 제시하고 있는 인장강도의 감소를 고려하여 제시하였다.
        54.
        2005.02 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        분리 대두단백질과 옥수수 전분을 혼합한 복합 필름의 막 특성을 이용하여 메추리알을 코팅하고 저장성 향상 및 품질 유지를 증대시키고자 하였으며 복합 필름을 복합조리식품(샌드위치)에 적용하여 식빵의 품질을 유지하기 위한 저장 실험을 하였다. 메추리알에 필름 용액을 코팅시킨 후 저장 중 Haugh unit yolk index, 중량변화를 측정하였다. 로 조절된 incubator에서 20일간 저장된 대조구와 복합 필름으로 코팅된 메추리알의 Haugh u
        1 2 3