        1.
        2017.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Four types of high Mn TWIP(Twinning Induced Plasticity) steels were fabricated by varying the Mn and Al content, and the tensile properties were measured at various strain rates and temperatures. An examination of the tensile properties at room temperature revealed an increase in strength with increasing strain rate because mobile dislocations interacted rapidly with the dislocations in localized regions, whereas elongation and the number of serrations decreased. The strength decreased with increasing temperature, whereas the elongation increased. A martensitic transformation occurred in the 18Mn, 22Mn and 18Mn1.6Al steels tested at −196 oC due to a decrease in the stacking fault energies with decreasing temperature. An examination of the tensile properties at −196 oC showed that the strength of the non-Al added high Mn TWIP steels was high, whereas the elongation was low because of the martensitic transformation and brittle fracture mode. Although a martensitic transformation did not occur in the 18Mn1.9Al steel, the strength increased with decreasing temperature because many twins formed in the early stages of the tensile test and interacted rapidly with the dislocations.
        4,000원
        2.
        2017.01 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This paper is concerned with a test method that can be used to investigate the parameters of the Johnson-Cook constitutive model. These parameters are essential for accurately analyzing material behavior under impact loading conditions in numerical simulation. Ti-6Al-4V alloy (HCP crytal structure) was used as a specimen for the experiments. In the 10−3-103/ s strain rate range, three types of experimental methods (convention, compression and tension) were employed to compare the differences using MTS-810, SHPB and SHTB. Finite element analysis results when applying these parameters were displayed along with the experiment results.
        4,000원
        3.
        2016.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In the present study, the tensile properties and dynamic strain aging of an Fe-24.5Mn-4Cr-0.45C alloy were investigated in terms of strain rate. During tensile testing at room temperature, all the stress-strain curves exhibited serrated plastic flows related to dynamic strain aging, regardless of the strain rate. Serration appeared right after yield stress at lower strain rates, while it was hardly observed at high strain rates. On the other hand, strain-rate sensitivity, indicating a general relationship between flow stress and strain rate at constant strain and temperature, changed from positive to negative as the strain increased. The negative strain-rate sensitivity can be explained by the Portevin Le Chatelier effect, which is associated with dynamic strain aging and is dependent on the strain rate because it is very likely that the dynamic strain aging phenomenon in high-manganese steels is involved in the interaction between moving dislocations and point-defect complexes.
        4,000원
        4.
        2010.01 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Yttria stabilized zirconia (Y-CSZ) single crystals show plastic deformation at high temperatures byactivating dislocations. The effect of strain rate on the plastic behavior of this crystal was studied. As increasingstrain rate from ε=1.04×10-5sec-1 to 2.08×10-5sec-1 the yield drop was suppressed and resulted in higherYoung's modulus and yield stress. Dislocation structures of the strained crystals were analyzed using atransmission electron microscope to elucidate the plastic behavior of these crystals. In the early stage of plasticdeformation, dislocation dipoles and prismatic dislocation loops were formed in both samples. However,dislocation density was increased by increasing strain rate. Strong sessile dislocations were observed in thesample with higher strain rate, which may cause the higher work hardening.
        4,000원
        6.
        2001.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고무제품에 근간을 둔 면진장치는 상당한 저온효과와 약간의 변형도 속도효과를 보여준다. 면진장치의 비탄성거동에 영향을 미치는 이들의 속성은 면진장치의 거동을 정확히 모델링하기 위해 반드시 고려되어져야 하기 때문에, 고무와 납 모두에 영향을 미치는 저온효과와 변형도 속도효과를 고려할 수 있는 해석모델을 제시하였다. 얼린 면진장치를 일정 수직하중에서 수평방향 반복하중을 가한 실험결과들로부터 시스템 식별(SI : system identification)을 적용하여 해석모델에 필요한 고무와 납의 매개변수들을 구하였다. 제안된 해석모델은 면진장치의 거동을 유사하게 표현할 수 있음을 보여준다.
        4,000원
        10.
        2019.10 서비스 종료(열람 제한)
        The purpose of this study was to evaluate the tensile fracture energy absorption capacity of hybrid fiber reinforced cement composite by strain rate. Experiment result, it was confirmed that PVA suppressed the microcrack around the HSF at the strain rate 101/s, which resulted in the improvement of the pullout resistance of the HSF.
        11.
        2019.10 서비스 종료(열람 제한)
        CFRP (Carbon Fiber Reinforced Plastic) has high tensile strength, light weight, and excellent corrosion resistance, so it is used for construction such as seismic reinforcement and explosion proof in construction area. Dynamic loads, such as earthquakes and explosions, cause rapid deformation of the material and the material behaves differently from its static condition. Therefore, in this study, tensile tests of CFRP were conducted under static and dynamic loads, and the tensile performance of was evaluated according to the strain rate.
        12.
        2019.04 서비스 종료(열람 제한)
        The purpose of this study was to evaluate the direct tensile fracture behavior of steel fiber hybrid reinforced cement composite by strain rate. Experiment result, it was confirmed that SSF suppressed the microcrack around the HSF at the strain rate 101/s, which resulted in the improvement of the pullout resistance of the HSF.
        13.
        2018.04 서비스 종료(열람 제한)
        The purpose of this study was to evaluate the direct tensile fracture behavior of fiber hybrid reinforced cement composite by strain rate. Experiment result, it was confirmed that PVA suppressed the microcrack around the steel fiber at the strain rate 101/s, which resulted in the improvement of the pullout resistance of the steel fiber.
        14.
        2017.12 KCI 등재 서비스 종료(열람 제한)
        In this study, the fiber blending ratio and strain rate effect on the tensile behavior of hybrid fiber reinforced cement composite was evaluated. Hooked steel fiber and polyvinyl alcohol fiber were used for reinforcing fiber. The fiber blending ratio of HSF+PVA were 1.5+0.5, 1.0+1.0 and 0.5+1.5vol.%. As a results, the tensile strength, strain capacity and fracture toughness of the hooked steel fiber reinforced cement composites were improved by the increase of the bond strength of the fiber and the matrix according to increase of strain rate. However, the tensile stress sharply decreased after the peak stress because of the decrease in the number of straightened pull-out fibers by micro cracks in the matrix around hooked steel fiber. On the other hand, PVA fiber showed cut-off fracture at strain rate 10-6/s with multiple cracks. However, at the strain rate 101/s, the multiple cracks and strain capacity were decreased because of the pull-out fracture of PVA fiber. The HSF1.5PVA0.5 shown the highest tensile strength because the PVA fiber suppressed the micro cracks in the matrix around the hooked steel fiber and improved the pull-out resistance of hooked steel fiber. Thus, DIF of strain capacity and fracture toughness of HSF1.5PVA were greatly improved. In addition, the synergistic response of fracture toughness was positive because the tensile stress was slowly decreased after the peak stress by improvement of the pull-out resistance of hooked steel fiber at strain rate 101/s
        15.
        2017.09 서비스 종료(열람 제한)
        The purpose of this study was to evaluate the tensile fracture behavior of fiber hybrid reinforced cement composite according to the strain rate. Experiment result, it was confirmed that the number of cracks and the strain capacity tended to decrease with increasing PVA fiber volume fraction at the strain rate of 101/s.
        16.
        2017.05 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 유압식 급속재하 시험 장치를 제작하여 변형 속도에 따른 후크형 강섬유 및 폴리아미드 섬유보강 시멘트 복합체의 압축강도 및 인장강도 특성을 평가하였다. 그 결과, 변형 속도가 증가함에 따라 압축강도, 최대 응력 점에서의 변형 및 탄성계수는 증가하였으 며, 섬유 종류 및 혼입률은 변형 속도에 의한 압축강도의 영향은 크지 않았다. 본 연구에서 평가된 압축강도의 DIF는 CEB-FIP model code 2010 에 비해 상회하였으며, ACI-349의 예측값과 유사한 경향이 나타났다. 인장특성의 경우에도 변형 속도가 증가함에 따라 인장강도와 변형능력 이 크게 향상되었다. 후크형 강섬유보강 시멘트 복합체는 변형 속도가 증가함에 따라 섬유와 매트릭스의 부착력이 증가하는 것에 의해 인장강 도와 변형능력이 크게 향상되었으며, 섬유가 매트릭스로부터 인발되는 파괴 특성이 나타났다. 한편, 폴리아미드 섬유보강 시멘트 복합체의 경 우 섬유와 매트릭스의 부착력이 크기 때문에 섬유가 매트릭스로부터 인발되지 않고 끊어지는 파괴 특성이 나타났으며, 폴리아미드 섬유보강 시멘트 복합체의 인장특성에 대한 변형 속도 효과는 섬유의 인장강도에 큰 영향을 받는 것으로 판단되었다. 이러한 결과로부터 폴리아미드 섬 유보강 시멘트 복합체의 인장강도에 대한 변형 속도의 효과는 후크형 강섬유의 부착력에 대한 민감도 보다 큰 것으로 사료된다.
        17.
        2016.10 서비스 종료(열람 제한)
        The purpose of this study was to evaluate the dynamic mechanical properties of fiber reinforced cement composite according to the strain rate. Experiment result, the compressive strength was improved by increase the strain rate. But strain at the peak stress and elastic modulus was not affected by the strain rate.
        18.
        2015.10 서비스 종료(열람 제한)
        To evaluate the compressive characteristics of concrete with high strain rate, SHPB(Split Hopkinson Pressure Bar) test is typically used. To verify the applicability and reliability of SHPB test for concrete, direct displacement image analysis with high speed camera was performed using plain concrete and UHPC.
        19.
        2015.07 KCI 등재 서비스 종료(열람 제한)
        충돌 또는 폭발 하중 하의 콘크리트는 정적 하중에서 가지는 재료물성과 다른 거동을 보이게 된다. 즉, 고변형율 하의 콘크리트의 재료물성은 크게 변화하게 되며, 이를 시험평가하기 위한 방법 중 압축강도와 관련된 시험법으로는 SHPB(Split Hopkinson Pressure Bar) Test가 있다. 그러나, SHPB Test는 금속과 같은 인성재료를 위해 개발된 시험방법으로서 취성재료인 콘크리트에 적용이 가능한지에 대한 검토가 추가적으로 필요하며, UHPC와 같은 섬유보강 초고성능 콘크리트에 대한 연구는 미미한 실정이다. 이에 본 연구에서는 콘크리트 시험체를 위해 제작된 SHPB Test 장비를 사용하여 일반 콘크리트 및 UHPC 시험체에 대한 시험평가를 수행하였으며, SHPB Test의 적용 적정성을 파악하기 위하여 초고속카메라를 활용한 변위영상 분석을 통한 검증을 수행하였다.
        20.
        2015.04 서비스 종료(열람 제한)
        Based on literature reviews, it was found that the dynamic increase factor, which is defined as the ratio of the dynamic strength to the static strength, is clearly dependent on specimen size, types, and experimental methods. It is expected that the proposed dynamic increase factor is significantly useful for numerical analysis of concrete behavior subjected to blast or impact.