검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Micro bubbles are widely used in many cases such as agriculture, fishery, skin care, prevention of water pollution. A high pressure compressor which is one of part of a micro bubble generating system is needed to generate these micro bubbles. The purpose of this research is the development of a high pressure compressor which is achieve following conditions; discharge flow 0.6ℓ/min, maximum air flow 2ℓ/min, discharge pressure 5bar. To achieve these conditions, we optimized the geometry of cylinder and piston, clearance volume, compression ratio, power of operating motor experimentally. Moreover, we minimized the compressor which is the biggest part of a micro bubble generating system so that we could minimized the size of entire system.
        4,000원
        2.
        1994.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents a new concept to reduce turbulent frictional drag by injecting micro-bubble into near the buffer layer of turbulent boundary layer on flat plate. The concentrations of micro bubble distribution in the boundary was calculater by eddy viscosity equations in the governing equations. When near region of the buffer layer of turbulent boundary layer is filled with micro-bulle of air and viscous of the region is kept low, the velocity profile in the near region should be changed substantially. Then the Reynolds stress in the region becomes less, which guide to lower velocity gradient there. It results in reduction of velocity gradient at the viscous sublayer, which gives the reduction of shear stress at the wall.
        4,000원
        3.
        2011.10 KCI 등재 서비스 종료(열람 제한)
        The objectives of this study are to examine the processing of oils contamination soil by means of using a micronano-bubble soil washing system, to investigate the various factors such as washing periods, the amount of micro-nano bubbles generated depending on the quantity of acid injection and quantity of air injection, to examine the features involved in the elimination of total petroleum hydrocarbons (TPHs) contained in the soil, and thus to evaluate the possibility of practical application on the field for the economic feasibility. The oils contaminated soil used in this study was collected from the 0~15 cm surface layer of an automobile junkyard located in U City. The collected soil was air-dried for 24 hours, and then the large particles and other substances contained in the soil were eliminated and filtered through sieve No.10 (2 mm) to secure consistency in the samples. The TPH concentration of the contaminated soil was found to be 4,914~5,998 mg/kg. The micronano-bubble soil washing system consists of the reactor, the flow equalization tank, the micronano- bubble generator, the pump and the strainer, and was manufactured with stainless material for withstanding acidic phase. When the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 30 minutes were respectively identified as 4,931 mg/kg (18.9%), 4,678 mg/kg (18.9%) and, 4,513 mg/kg (17.7%). And when the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 120 minutes were respectively identified as4,256 mg/kg (22.3%), 4,621 mg/kg (19.7%) and 4,268 mg/kg (25.9%).
        4.
        2011.03 KCI 등재 서비스 종료(열람 제한)
        The main objectives of this research are to investigate characteristics of ozone solubility due to low solubility of conventional bubbles-ozone generators, evaluate the treatment characteristics of reclaiming textile wastewater for industrial water by means of micro/nano bubbles-dissolved ozone flotation(MNB-DOF) process. The textile wastewater used in this research was obtained from final effluent of the textile wastewater in B city. There is a 400L reactor which consists of a micro-nano bubble system and a ozone generator for experiments. As a result of generating micro-nano bubbles (below 0.5 ㎛) by using of MNB-DOF process, it improved ozone solubility due to higher ozone transfer rates. Consequently, the shorter ozonation time clearly indicates the lower power costs. The reported results clearly indicated that MNB-DOF process can be effectively and inexpensively. Results of the experiments through MNB-DOF process in this study satisfy all reclaiming standards as industrial water: pH 6.5~8.5, SS 10 mg/L or below, BOD_5 6 mg/L or below, turbidity 10 NTU or below, Coliforms 1,000/100 mL or below. Therefore there is a possibility of the reclaiming of the textile wastewater as industrial water.
        5.
        2010.05 KCI 등재 서비스 종료(열람 제한)
        The objectives of this research are to evaluate and compare the oxygen transfer coefficients(KLa) in both a general bubbles reactor and a micro-nano bubbles reactor for effective operation in sewage treatment plants, and to understand the effect on microbial kinetic parameters of biomass growth for optimal biological treatment in sewage treatment plants when the micro-nano bubbles reactor is applied. Oxygen transfer coefficients(KLa) of tap water and effluent of primary clarifier were determined. The oxygen transfer coefficients of the tap water for the general bubbles reactor and micro-nano bubbles reactor were found to be 0.28 hr -1 and 2.50 hr -1 , respectively. The oxygen transfer coefficients of the effluent of the primary clarifier for the general bubbles reactor and micro-nano bubbles reactor were found be to 0.15 hr -1 and 0.91 hr -1 , respectively. In order to figure out kinetic parameters of biomass growth for the general bubbles reactor and micro-nano bubbles reactor, oxygen uptake rates(OURs) in the saturated effluent of the primary clarifier were measured with the general bubbles reactor and micro-nano bubbles reactor. The OURs of in the saturated effluent of the primary clarifier with the general bubbles reactor and micro-nano bubbles reactor were 0.0294 mg O2/L․hr and 0.0465 mg O2/L․hr, respectively. The higher micro-nano bubbles reactor's oxygen transfer coefficient increases the OURs. In addition, the maximum readily biodegradable substrate utilization rates(Kms) for the general bubbles reactor and micro-nano bubbles reactor were 3.41 mg COD utilized/mg active VSS․day and 7.07 mg COD utilized/mg active VSS․day, respectively. The maximum specific biomass growth rates for heterotrophic biomass(μmax) were calculated by both values of yield for heterotrophic biomass(YH) and the maximum readily biodegradable substrate utilization rates(Kms). The values of μmax for the general bubbles reactor and micro-nano bubbles reactor were 1.62 day -1 and 3.36 day -1 , respectively. The reported results show that the micro-nano bubbles reactor increased air-liquid contact area. This method could remove dissolved organic matters and nutrients efficiently and effectively.
        6.
        2007.06 KCI 등재 서비스 종료(열람 제한)
        Many lakes or irrigative reservoirs in Korea are rapidly contaminated due to the ever increasing pollutants. Although lots of treatment processes have been recommended and practiced, economical and technical improvement is currently needed. In this study, contaminated irrigation reservoir was treated using the proposed process which is consisted of fine air bubbles, coagulation and flotation. Fine bubbles, approximate diameter of 3 to 10 ㎛, were generated using cavitation in the pressurized tank and polyaluminum chloride was used as coagulants. This fine bubbles, coagulation and flotation effectively controlled the low density algae, for example, Chlorophyll-a was removed more than 97 %. Removal efficiency of COD, SS, T-N and T-P were 80.7%, 94.3%, 64.1% and 92.4%, respectively. Pollutants released from the sediments was removed more than 80% of organics and 60-70 % of nutrients. Consequently, fine bubbles coagulation and flotation process could be effectively used as an alternative treatment method for the purpose of control of lake water quality.