This study was conducted to improve the analytical method of siloxanes in biogas. Methanol and hexane were tested as absorption solvents of the impinger absorption method, and also the hexane extraction for pretreatment of sample was evaluated. Manufactured gas contained siloxanes of 50 ppm was completely absorbed by the methanol impinger absorption. The absorption efficiency of biogas containing only 2 ppm, however, was maximum 84%. As the condensate on the first impinger increased, the absorption rate of methanol was decreased. The hexane extraction method of the sample was considered to proper the method of moisture removal. The hexane extraction result showed the high recovery factor and the low relative standard deviation. It is suggested that the suitable choice of solvent and pretreatment is required, as the analysis result of siloxane sample may be differentiated depending on the type of biogas or the sampling point.