In this study, vertical extension type TMD(VE-TMD) whose vertically extended stories behave like a tuned mass damper, with Lead-Rubber Bearing(LRB) between the top of existing structures and the bottom of the extended stories was proposed. A shaking table tests for a 5-story reinforced concrete model, which is of 2.2 Hz natural frequency. A vertical extended model consisted of a steel frame, with two base isolators between the top of the RC model and the bottom of the extended stories. Those base isolators' lateral stiffness was equal to 31.392 kN/m which was calculated with the fundamental period plus 0.2 tonf, weight of a single story of the model. The test for the specimen was shaking table test excited by a harmonic loads for the fundamental period of the structure. The test results indicated that the VE-TMD improved seismic performance by 40 % in displacement responses for all of frequency-domain.