In this study, EL. 610 test and SHRP H-205.8 test were performed to evaluate the effects of deicing salts on concrete. According to the test results, EL. 610 chemical deicer test method was not enough to evaluate the chemical effects on concrete. On the contrary, the results of SHRP H-205.8 test method showed clear distinction between deicer type A and type B.