논문 상세보기

강판보강 커플링보의 내진성능평가를 위한 유한요소해석

Seismic Evaluation Of Coupling Beam Reinforced With Steel Plate By FEA

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/292659
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

For coupled shear walls, coupling beams are the first line of dissipation under earthquakes. So coupling beams are important energy dissipation component. When coupling beams have little depth-to-span ratio, routine coupling beams have less capacity of energy dissipation.There are less design methods for coupling beams with depth-to-span less than 2. In this paper a specimen with steel plate reinforcement coupling beam was designed and analyzed by means of FEM software ABAQUS.

저자
  • 진유의(충남대 대학원 석사과정) | Chen, Liu-Yi
  • 이강민(충남대 건축공학과 교수, 공학박사) | Lee Kang-min
  • 천영수(한국토지주택공사, 토지주택연구원) | Chun Young-Soo
  • 이예(충남대학교 석사과정) | Li, Rui
  • 오근영(충남대학교 석사과정) | Oh, Keun-Yeong