초록

The purpose of this study is to confirm the removal effect of odorous gas through the multi process. The combination of Scrubber, UV and Adsorption was analyzed using the odor gas of reservoir. Analysis was carried out for six times in total and collection was made once per each process. Sampling was performed in the afternoon during August (1:00 pm~4:00 pm). Multi process has been designed to facilitates the accessories exchange. The advantage is that it facilitates the replacement of the activated carbon and it is convenient to change the type of chemical according to the type of pollution materials. As a result, for odor gas removal efficiency, ammonia 91.8%, trimethylamine 72.0%, hydrogen sulfide 99.9%, methyl mercaptan 99.9% were removed respectively. Removal efficiency of the process is the scrubber (alkali), activated carbon adsorption, scrubber (acid) and UV procedure from the highest order. Further studies on the operating method and efficiency of multi process by the change of wind speed and chemical are recommended.

저자
  • 권우택(을지대학교 보건환경안전학과) | Woo-Taeg Kwon
  • 이준철(을지대학교 보건환경안전학과) | Jun-Cheoul Lee
  • 강형석(을지대학교 보건환경안전학과) | Hyoung-Seok Kang
  • 권이승(가톨릭관동대 의료경영학과) | Lee-Seung Kwon
  • 김희곤(선일환경주식회사) | Hee-Gon Kim
  • 갈원모(을지대학교 보건환경안전학과) | Won-Mo Gal Corresponding author