Combustion Characteristics in a Commercial Scale SRF Incinerator with High Temperature Exhaust Gas Recirculation
Characteristics of exhaust gas of solid refuse fuel (SRF) burning in a commercial scale of 12ton/day incinerator havebeen investigated. Combustion air for SRF burning is mixed with recirculated high temperature exhaust gas to diluteoxygen concentration and preheat itself. It is called high temperature EGR (Exhaust Gas Recirculation) combustion. Itis known that low oxygen concentration of diluted air reduces flame temperature and NOx emission, but also makes flameunstable. Highly heated air by mixing with high temperature exhaust gas makes flame stable by enhancement ofcombustion reaction. Concentrations of nitric oxide (NOx), carbon monoxide (CO), oxygen (O2) and carbon dioxide (CO2)in flue gas have been measured at stack. High temperature EGR incineration of SRF dramatically reduces nitric oxideemission and residual oxygen. Average concentrations of NOx, and CO are 71.5ppm and 86.6ppm especially at referenceoxygen concentration of 12% without any post treatment of NOx when the average outlet temperature of combustionchamber is 942oC. And average concentrations of O2 and CO2 are 9.59% and 8.3% especially.