Cap decks used in slim floor system for reducing floor height act as molds for forming floor slabs in structures with a span of up to 6m without temporary supports. When deep decks are employed in a structure with a span of more than 6m, the problem of defection occurs. This study suggests placing tendons at the ends of cap decks in order to create cambers and control defection when preload is applied. Uniformly distributed load was applied by an UTM to the two L/4 points of specimens to observe the deflection of preloaded cap decks. For the test, three 7.5m specimens were fabricated. One of them was a plain cap deck specimen and the others were those with tendons (PC strands or steel bars.