초록

This study compares characteristic of membrane fouling in MBR-RO systems. In lab. scale MBRs test, MBRs were operated at different Flux(10, 20, 30 & 40 LMH) and temperature(10, 15, 20, 25 & 30°C). The results show that MBR permeate was measured lower amounts of organic substances in Higher flux and lower temperature and led to lower RO fouling rates. The main cause was that due to cake fouling formed on membrane surfaces in MBRs. Under both cases, Cake layer of membrane surfaces formed in MBRs removed RO fouling factors, polysaccharide and protein, because of cake layer attached on membrane surfaces greater amounts of organic substances. This study implies that optimization of MBR with operating conditions is a crucial strategy to RO membrane fouling control.