논문 상세보기

공기청정기의 일부 실내공기 오염물질 제거효율에 관한 연구 KCI 등재

Efficiency of Removal for Indoor air pollutants by Air Cleaners in the Indoor Environments

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/363416
서비스가 종료되어 열람이 제한될 수 있습니다.
한국환경과학회지 (Journal of Environmental Science International)
한국환경과학회 (The Korean Environmental Sciences Society)
초록

In this study, we investigated PM10, NO2, and 1-hydroxypyrene(1-OHP) in urine at indoor environments which are 35 houses and 20 hospitals for using air cleaner and non-using air cleaner in Seoul metropolitan area and Kyoung-gi province from April, 2003 to February, 2004. Moreover, we examined effect of improvement for indoor air quality and health effect by concentration of 1-OHP also we investigated removal efficiency by air cleaner for PM10, NO2, and 1-OHP that were 28.5%, 27.4%, and 42.1% respectively. Concentration of PM10, NO2, and 1-OHP were 19.02±18.14㎍/m3, 8.66±3.06ppb, and 0.19±0.18㎍/g creatinine when air cleaner was no worked. The concentration for PM10, NO2, and 1-OHP were 13.60±10.79㎍/m3, 6.29±2.71ppb, and 0.11±0.10㎍/g creatinine, respectively. It was significant statistically. Therefore, it is considered using the air cleaner to remove the partial pollutants in indoor environment and is positive effect for health.

저자
  • 이태형(한양대학교 환경 및 산업의학연구소, 국립환경연구원 실내환경연구사업단) | Tae-Hyung Lee
  • 김윤신(한양대학교 환경 및 산업의학연구소) | Yoon-Shin Kim Corresponding Author
  • 홍승철(한양대학교 환경 및 산업의학연구소, 인제대학교 보건안정공학과) | Seung-Cheol Hong
  • 이철민(한양대학교 환경 및 산업의학연구소) | Cheol-Min Lee
  • 김종철(한양대학교 환경 및 산업의학연구소) | Jong-Cheol Kim
  • 전형진(한양대학교 환경 및 산업의학연구소) | Hyung-Jin Jeon
  • 김중호(삼성전자(주) 생활가전총괄) | Jung-Ho Kim