논문 상세보기

유동층 연소로에서 유 · 무연탄 혼합 연소법을 이용한 국내산 저질 무연탄의 활용에 관한 연구 KCI 등재

A Study on the Use of Low - Grade Domestic Anthracite by Anthracite - Bituminous Coal Blend Combustion in a Fluidized Bed Combustor

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/366905
서비스가 종료되어 열람이 제한될 수 있습니다.
한국환경과학회지 (Journal of Environmental Science International)
한국환경과학회 (The Korean Environmental Sciences Society)
초록

It has been studied that combustion and the production of air pollution of anthracite - bituminous coal blend in a fluidized bed coal combustor. The objects of this study were to investigate mixing characteristics of the particles as well as the combustibility of the low grade domestic anthracite coal and imported high calorific bituminous coal in the fluidized bed coal combustor. They were used as coal samples ; the domestic low grade anthracite coal with heating value of 2,010㎉/㎏ and the imported high grade bituminous coal with heating value of 6,520㎉/㎏. Also, the effects of air flow rate and anthracite fraction on the reaching time of steady state condition have been studied. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 300scfh which was the fastest. It has been found that O_2 and CO_2 concentration were reached steady state at about 100 minute. It has been found that O_2 concentration decreased and CO_2 concentration increased as the height of fluidized bed increased. It was found that splash zone was mainly located from 25㎝ to 35㎝ above distributor. Also, as anthracite fraction increased, the mass of elutriation particles increased, and CO_2 concentration decreased. As air flow rate increased, O_2 concentration decreased and CO_2 concentration increased. Regardless of anthracite fraction and flow rate, the uncombustible weight percentage according to average diameter of elutriation particles were approximately high in the case of fine particles. As anthracite fraction and air flow rate increased, elutriation ratio increased. As anthracite fraction was increased, exit combustible content over feeding combustible content was increased. Regardless of anthracite fraction, size distribution of bed material from discharge was almost constant. Over bed temperature 850℃ and excess air 20%, the difference of combution efficiencies were little. It is estimate that the combustion condition in anthracite-bituminous coal blend combustion is suitable at the velocity 0.3m/s, bed temperature 850℃, the excess air 20%.

저자
  • 정종현(경주전문대학 환경공업과) | Jong-Hyeon Jung (Dept. of Environmental Industry, Kyong-Ju Junior College)
  • 조상원(창원기능대학 환경기술학과) | Sang-Won Cho (Dept. of Environmental Technology, Changwon PoIytechnic College)
  • 손병현(한서대학교 환경과학과) | Byung-Hyun Shon (Dept. of Environmental Science, Hanseo Univ.)
  • 전영화(부산대학교 환경공학과) | Young-Hwa Jeon (Dept. of Environmental Engineering, Pusan National Univ.)
  • 오광중(부산대학교 환경공학과) | Kwang-Joong Oh (Dept. of Environmental Engineering, Pusan National Univ.)