아연 이온화 장치에 의한 상수배관 내 스케일 및 녹 생성 억제효과 실증 연구 KCI 등재

Empirical study on inhibition effect of scale and rust in tap-water line by zinc ionization device

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/411890
구독 기관 인증 시 무료 이용이 가능합니다. 4,200원
상하수도학회지 (Journal of the Korean Society of Water and Wastewater)
대한상하수도학회 (Korean Society Of Water And Wastewater)
초록

Scale and rust generation in water pipes is a common phenomenon when cast iron water pipes have been used for a long time. A physical water treatment device is known among various means for suppressing rust in a water pipe, and a zinc ionization device for putting zinc metal into a pipe and emitting the zinc cation into water is one of such devices. This research measured the amount of zinc ion generated, which is known to exhibit an effect of inhibiting rust and scale generation in a pipe, and examined the scale and rust inhibition effect of the ionization device installed for ground or building water supply. In the case of distilled water, the concentration of zinc ion increased by circulating water in the ionization device several times, and it was verified to be hundreds of μg/L, and in the case of discharging ground or tap water, it was verified to be tens of μg/L. In addition, a verification pipe was installed to confirm the change inside the pipe before and after installation of the zinc ionization device, and the internal condition of the pipe was observed 3 months to several years after installation. It was confirmed that the corrosion area of the surface of the pipe was no longer increased by installing a corrosion inhibitor, and if the pipe was already filled with corrosion products, the amount of corrosion products gradually decreased every year after installation. The phenomenon of fewer corrosion products could be interpreted as expanding the space in the pipe due to the corrosion product as Fe2O3 adhered to the inner surface of the pipe and turned into a smaller black Fe3O4. In addition, we found that scale such as CaCO3 together in the corrosion by-products gradually decreased with the attachment of the ionization device.

목차
ABSTRACT
1. 서 론
2. 연구내용 및 방법
    2.1 아연이온화 장치
    2.2. 연구대상 상수관
    2.3. 부식억제효과 평가
3. 결과 및 고찰
    3.1 이온화 장치에 의한 수질 변화
    3.2 이온화장치에 의한 상수배관에서의 녹 억제 효과
    3.3 아연이온에 의한 급수관 부식생성물 억제효과 원리
4. 결 론
References
저자
  • 염경택(성균관대학교 수자원전문대학원) | Kyung-Taek Yum (Graduate School of Water Resources, Sungkyunkwan University)
  • 최정욱(진행워터웨이) | Jung-Wook Choi (Jinhaeng Waterway)
  • 양성봉(진행워터웨이) | Sung-Bong Yang (Jinhaeng Waterway)
  • 양성봉(진행워터웨이) | Sung-Bong Yang (Jinhaeng Waterway)
  • 유미선(울산대학교 건설환경공학부) | Mee-Seon Yu (School of Civil & Environment Engineering, University of Ulsan) Corresponding author