This research studied faults that may occur during slow charging using the J1772 adapter of Tesla Model-3 electric vehicles. When the AC terminal was instantaneously disconnected, charging was performed normally when an AC circuit with disconnection up to three disconnection times was connected. Charging control was suspended when the number of disconnection reached four times. However, if the AC disconnection time exceeded 22 seconds, the charging control was stopped regardless of the number of disconnection. When a contact failure occurred at the AC terminal, high surge current and noise occurred. However, when the contact improved, the charging control continued. In terms of safety, it seems necessary to take measures such as stopping charging control when detecting noise.