논문 상세보기

A Case Study on Demonstration of Compliance of Dose Criteria for Site and Building Reuse of Foreign Cyclotron Facilities

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/431434
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

For safe and successful decommissioning, it is one of the most important procedures that establishing the goal and complying with regulations of which final status of decommissioned site and building. The dose criteria for cyclotron facilities should be established and applied to reuse the site and building, since building and component of a cyclotron facility have been activated by incident secondary neutrons from radioactive isotope processes (e.g. 18O(p,n)18F, etc.). Furthermore, appropriate approaches should be applied to demonstrate compliance with the dose criteria for reliability of reuse. It is of noted that U.S. NRC (Nuclear Regulatory Commission) has confirmed that the residual radioactivity which distinguishable from background radiation results in a TEDE (Total Effective Dose Equivalent) does not exceed 25 mrem (0.25 mSv) per year as radiological criteria for unrestricted use of not only nuclear power plants but also cyclotron facilities referred to 10 CFR Part 20.1402. In addition, U.S. NRC noted the two approaches (i.e. dose assessment methods and, DCGL and final status surveys) which can be applied for demonstrating compliance with the dose criteria of 10 CFR Part 20 and recommended DCGL and FSS approach based on advantages and disadvantages of the two approaches. In order to using DCGL and FSS approach, U.S. NRC suggested screening approach; using DandD Version 2 which assesses TEDE under ICRP 28 and site-specific approach; using all models or computational codes which approved by NRC staff. There are several foreign cases that release of cyclotron facilities after decommissioning (i.e. U.S. and Japan). U.S., for examples, there are two DCGL approach cases and one dose modeling case based on 25 mrem per year same as reactor facilities. The dose modeling case, however, which may not be really used in Korea because of its low applicability. On the other hand, Japan case did not establish any radiological criteria for site and building reuse such as DCGL and just confirm “no more contamination” which is all residual radioactivity is lower than MDC based on real survey. Japan case also may not be used in Korea since criteria of “no more contamination” is not clear and hard to apply for all sites. Considering regulations and criteria for site release and reuse in Korea, this study aims to suggest radiological criteria and the demonstration approach of compliance for decommissioning of cyclotron facilities based on Nuclear Safety Acts and NSSC notices.

저자
  • Se Geun Lee(Korea Research Institute of Decommissioning (KRID))
  • Jae Hak Cheong(Kyung Hee University) Corresponding author