논문 상세보기

아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안 KCI 등재

Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/435426
구독 기관 인증 시 무료 이용이 가능합니다. 4,500원
대한안전경영과학회지 (Journal of Korea Safety Management & Science)
대한안전경영과학회 (Korea Safety Management & Science)
초록

This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

목차
1. 서 론
2. 실험구성 및 모델
3. 시나리오 구성
    3.1 ALOHA, Pathfinder 프로그램 및 피해 영향평가
    3.2 사고시나리오
4. 실험 결과
    4.1 아크릴로니트릴의 영향범위 및 LOC 도달시간
    4.2 아크릴로니트릴의 누출에 따른 피난 시간
5. 실험 분석
    5.1 아크릴로니트릴의 독성 평가
    5.2 아크릴로니트릴의 복사열 평가
    5.3 실험분석에 따른 성능위주설계 방안
6. 결 론
7. References
저자 소개
저자
  • 오승주(우석대학교 일반대학원 소방안전공학과 박사과정) | Seongju Oh (Ph.D. Candidate Dept. of Fire Protection & Safety Engineering, Woosuk University)
  • 한상훈(우석대학교 일반대학원 소방안전공학과 박사과정) | Sanghun Han (Ph.D. Candidate Dept. of Fire Protection & Safety Engineering, Woosuk University)
  • 공하성(우석대학교 소방방재학과 교수) | Hasung Kong (Associate Professor, Fire and Disaster Prevention, Woosuk University) Corresponding author