간행물

한국실내환경학회지 KCI 등재후보 Journal of Korean Society for Indoor Environment

권호리스트/논문검색
이 간행물 논문 검색

권호

Vol. 9 No. 4 (2012년 12월) 5

1.
2012.12 구독 인증기관 무료, 개인회원 유료
This study was performed to evaluate the type and concentration of TVOC and formaldehyde emitted from asbestos stabilizers, because the stabilizers can be applied on the surface of asbestos contained building materials(ACBM). The emission test of three organic and synthetic resins(OSBS) and five inorganic based stabilizers(IBS) were tested for 7 days. The amount of emission and concentrations of TVOC were measured using GC/FID and GC/MS. In case of formaldehyde, quantitative analysis was carried out using HPLC. The average concentrations of TVOC and formaldehyde of 8 stabilizers were 1.173 mg/m2․h and 0.007 mg/m2․h, respectively. The maximum TVOC concentration among five OSBS was 5.698 mg/m2․h and exceeded the TVOC emission standard(4.0 mg/m2․h) for general building materials. According to the this study results, the applied stabilizer can be role one of pollutant sources like paints, floor tile etc. The emission test has to be tested one of stabilizers efficiency to manage the indoor air quality of building.
4,200원
2.
2012.12 구독 인증기관 무료, 개인회원 유료
This study is to consider the introduction of the standard practice which test the asbestos stabilizer efficiency for the spray-applied ACBM, because asbestos stabilizer may be one of operation & management (O&M) program to prevent friable asbestos from spray-applied asbestos containing building materials( ACBM) and some countries like U.S and Japan have introduced the evaluation system or standard practice to test the efficiency of asbestos stabilizer which is used for spray-applied ACBM since 2002 and 2006, relatively. Efficiency test of 8 stabilizers which were manufactured from Japan, Australia and Korea was performed by the method of the Ministry of Land, Infrastructure, Transport and Tourism of Japan. The contents of test method were consisted adhesive strength, penetration depth, impact resistance and wind affection. The efficiency of impact resistance and wind affection was improved 4.1~37.4% and 75.2~95.7% after asbestos stabilizer applied on the spray-applied ACBM. Although the results of adhesive strength were less than that of non-applied materials but that was satisfied the ASTM standard (2.4kPa).
4,000원
3.
2012.12 구독 인증기관 무료, 개인회원 유료
Information on time spent in microenvironments has a critical role in individuals’ exposure assessment. Time-activity studies have become an integral part of comprehensive exposure assessment and personal exposure modeling. The aims of this study were to estimate the exposure level of NO2, PM10 and VOCs, and to compare the estimated exposure by using time-activity pattern and indoor air concentration. This study was performed upon 28 university students living in Daegu. We measured air pollutants of NO2, PM10 and VOCs at houses where the university students spent most their times. In this study, according to the summer and winter, time-activity patterns of university students were different. The 28 university students average spending times in house indoors and other indoors time were 11.52±2.14 and 7.63±2.65 hours in summer, and 14.78±3.30 and 6.59±3.03 hours in winter, respectively. The university students personal exposure NO2 concentrations were average 21.62±5.88 ppb and I/O ratio was 0.89±0.27. Personal average exposure of PM10 concentration was between house indoors and outdoors concentrations which indoor house concentration was 37.68±7.57 μg/m3 and outdoor house concentration was 43.85±9.80 μg/m3 with 0.88±0.17 of I/O ratio. Personal exposure to benzene and the average concentration of benzene did not exceed in atmosphere environmental standard (annual 1.5 ppb) and the outdoor houses concentration was much higher than indoor houses.
4,200원
4.
2012.12 구독 인증기관 무료, 개인회원 유료
The objective of the present study was to estimate the health risk level for children exposed to phthalate and identify the pathways including indoor floor dust, surface wipe and hand wipe in elementary-schools and institutes. The samples of indoor place were collected at children's facilities (50 elementary-schools and 46 academies) in summer (Aug ~ Sept, 2008), winter (Dec 2008 ~ Feb, 2009) and Spring (Mar ~ Apr, 2009) periods. Hazard Index (HI) were estimated for the non-carcinogens and the examined phthalate were diethylhexyl phthalate (DEHP), dibutyl-n-butyl phthalate (DnBP), butylbenzyl phthalate (BBzP). Risk analysis indicates that did not exceed 0.01 (HI) for all subjects in all facilities it's 50th % and 95th % value. For DEHP, DnBP and BBzP their detection rates through multi-pathways were high and their risk based on health risk assessment was also observed to be acceptable.
4,800원
5.
2012.12 구독 인증기관 무료, 개인회원 유료
This study investigated the effect of smoking on Indoor Air Quality in smoking allowed buildings. Total 26 buildings(Restaurants 3, Billiards 4, Karaokes 6, Golfs 7, Pubs 6) were surveyed for nicotine, PM10, CO2, CO, NO2, HCHO, TVOCs, benzene, toluene, ethylbenzene, styrene and xylene at quiet and busy time, respectively. The concentrations of nicotine, PM10, CO2 and benzene were significantly higher(p<0.05) at busy time compared to the quiet time. Some buildings exceeded Indoor Air Quality Standards for PM10, CO2, HCHO and TVOCs. Our results show that smoking-ban legistration should be introduced to improve Indoor Air Quality.
4,200원