이 연구에서는 최근 개발된 강섬유 보강 초고성능 콘크리트(UHPSFRC)의 압축연화 거동을 실험을 통해 측정하였다. 압축 연화곡선을 안정적으로 측정하기 위해 실험체의 횡 방향 변형을 제어하여 실험을 수행하였다. 실험에 사용한 UHPFRC의 배 합은 모두 세 가지(M1, M2, M3)이며, 평균 압축강도는 각각 순서대로 131.0, 161.6, 171.5 MPa로 측정되었다. 압축강도와 섬유함유량에 따라 압축연화곡선의 거동이 다르게 나타났다.
The rheological properties of concrete vary during pumping. In this study, the tests were conducted to evaluate whether changes in rheological properties of concrete during pumping occur only by pressure, or by both pressure and shear flow. A high-strength concrete with a design strength of 50 MPa was used in the experiment. From the test results, it was confirmed that the change of rheological properties of concrete during pumping was affected by both pressure and shear flow.
The core is extracted to evaluate the concrete compressive strength of the actual structure. However, the core strength can vary in the core size due to two reasons - size effect in fracture mechanics and effect of coring damage. Therefore, the purpose of this study was to assess quantitatively the difference in strength due to these effects. The core damage tended to increase relatively as the core section was smaller. The strength difference due to the size effect in fracture mechanics did not show any significant difference according to the curing condition and was measured to be similar to the previous study.
최근 수송선박의 대형화에 따라 기존 항만 시설의 접안 깊이 확보에 대한 필요성이 증가하고 있다. 증심공법은 기존 항만시설의 접 안 깊이를 확보하는 방법으로, 필요 깊이만큼 사석마운드를 굴착한 후 그라우팅을 통해 보강한다. 이 연구에서는 사석마운드 보강을 위한 그라 우팅 재료로 가소성 그라우트를 사용할 경우 보강성능과 충진성능에 대해 검토하고자 하였다. 2가지 가소성 그라우트 배합에 대해 압축강도 실험을 수행하여 지반보강효과를 검토하였고, 직경 400 mm, 높이 530 mm 크기의 실린더형 실험체 5개를 제작해 충진성능을 평가하였다. 구 조물의 안전성 확보를 위해 요구되는 개량체의 소요강도는 6 MPa이며, 이 연구에서 사용한 가소성 그라우트 배합 모두 재령 7일에 9 MPa 이상 으로 소요강도를 만족하는 것으로 확인되었다. 충진성능 평가 실험체의 충진상태를 육안으로 관찰한 결과, 이 연구에서 목표로 설정한 사석 채 움 높이까지 가소성 그라우트가 잘 채워지는 것을 확인하였다.
The influence of mineral admixture content on the bleeding of cement-based grouts. Replacement of fly ash increased the bleeding, but the increase of the content of blast furnace slag as well as silica fume led to the reduction in the bleeding. Especially 15% replacement of silica fume showed the best performance against normal bleeding as well as channel bleeding.
A method to measure rheological properties of cementitious materials through mini slump test has been previously suggested. In this study, experiments were performed to verify that method. As the mini slump test proceeds, the spreading diameter of the material were measured by using a digital image processing technique. From the measured spreading diameter versus time curve, the rheological properties were estimated and compared to the properties measured from the viscometer.
For hybrid fiber reinforced UHPC with two kinds of steel fibers, variation of the flexural behavior with different fiber distribution characteristics was estimated by experiments, and a prediction of the flexural behavior using smeared crack model. it was found that adopting a crack bandwidth considering the fiber distribution characteristics enable to predict the fractural behavior of UHPC beam.
It is difficult to ensure enough workability and flowability in the fresh state of UHPC. In addition,
it needs to enhance economic efficiency by reducing the usage of expensive constituents. Zirconia silica fume is an alternative material to replace the existing Silica fume. The objective of this study is to find out the effect of Zirconia silica fume dosage on viscosity of UHPC matrix
Mechanical performance of UHPC is known to be strongly influenced by placing method. In this study, in order to estimate variation in tensile behavior of hybrid fiber reinforced UHPC, two different placing methods were adopted in fabricating test specimens. Test results presents that placing method causes a noticeable variation in the tensile behavior
실제 교량의 바닥판에 적용할 목적으로 섬유의 길이 및 혼입량을 달리한 두 가지 초고성능 시멘트 복합체를 고려하고 있다. 이 연구의 목적은 이 두 재료의 균열저항성을 평가하는 것이다. 두 재료에 대한 휨인장 파괴실험을 수행하였고, 실험으로부터 얻은 하중-균열개구변위 관계를 최적으로 모사하는 인장응력-균열개구 관계를 역해석을 통해 파악하였다. 역해석결과 13 mm 길이의 섬유를 2% 함유한 UHPCC는 16.3 mm와 19.5 mm 길이의 섬유를 각각 0.5%와 1.0% 함유한 UHPCC에 비해 파괴에너지가 작은 것으로 나타났다. 균열을 보다 분산시키고 균열폭을 감소시키기 위해서는 길이가 긴 두 종류의 섬유를 혼용한 UHPCC를 사용하는 것이 바람직할 것으로 판단된다.