The priority order about a rational repair and reinforcement is generally decided by subjective decision of engineer. An appearance investigation carried out to decide about a rational repair and reinforcement through systematic and objective analysis in tunnel. we could prevent expecting leakage through several improvements in the aspects of design, materials and site implementation.
The priority order about a rational repair and reinforcement is generally decided by subjective decision of engineer. An appearance investigation carried out to decide about a rational repair and reinforcement through systematic and objective analysis in tunnel. we could prevent expecting leakage through several improvements in the aspects of design, materials and site implementation.
Concrete is generally accepted to have good fire resistance. It mainly relies on the assumption that concrete has low heat-transfer characteristic and spalling does not occur during the course of a fire. However, the significant numbers of fire accidents have shown in recent years that incidence of spalling has caused sever damages to many structures. This research has investigated a series of catastrophic tunnel fires and tested on the behaviour properties of concrete in association with loading in fire. This paper present that the theoretical consideration and experimental results are used the information of concrete spalling.