The Microfiltration and Ultrafiltration were used to treat effluent of secondary municipal wastewater treatment system(Sequencing Batch Reactor). The cross-flow hollow fiber, UF 500,000(NMWC) and MF 0.65μ membrane were selected as suitable membrane. Short term and long term fouling effect were measured as a factor of flux decrease and the fouling removal effect of mixing air bubble in the penetrant was studied. The removal of anionic sulfactants before and after formation of micelle with several kinds of oil were checked. The test results show that removal of TOC was 70~80%, TN 28% and TP 16%. The decrease of flux due to fouling were 85%(UF) and 90%(MF) after running of 100hrs. The removal of anionic sulfactants were 60~70% notwithstanding micelle or not.
There are several serious problems in treating shipboard wastewater due to special environmental conditions of ship, such as confined space, rolling and pitching, change of temperature and so on. It was suggested that Sequence Batch Reator (SBR) process might be suitable for overcoming above problems in terms of small size, high capacity of treating wastewater and full automation. In this study the SBR process was used for the secondary treatment of shipboard wastewater. The average removal efficiency of DOC, nitrogen, phosphorus and surfactants(MBAS) were studied and the effects of various C/N ration on the efficiency of treatment were investgated. From the experimental results it was convinced that the SBR process would be able to be used as a suitable process for removing organic matters and nitrogen in reuse system of shipboard wastewater.