검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 10

        5.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is intended to Mindori structure which is general private houses' structural type among traditional types and is a basic study to confirm structural characteristics of Hwatong connection which is general connection type of column-beam-cross beam. It is aimed to analyze how main member ,column, such as size, figure, thickness of Sungetuk and Dugeup affect on structure. Following conclusions are drawn. 1. According to connection conditions, models with big coefficient of friction show stable hysteretic behavior until the angle rotation of member reaches 1/60 and models with small coefficient of friction show dramatical increase in load after the angle rotation of member reaches 1/24. After the angle rotation of member reaches 1/30, separation distance of members is identified physically and cracks are not observed. 2. Specimens with big coefficient of friction show similar inner force regardless of column size(except column size 150mm) and models with small coefficient of friction show increasing inner force as the column size increases. Specimens with same sectional area have similar inner force even though the column figures are different. The thickness of Sungetuk and Dugeup doesn't affect inner force greatly, however, when the thickness of Sungetuk is thin, it could lead to failure of structure as it breaks. 3. The bigger the size of column and the coefficient of friction are, the smaller Bending stiffness depreciation ratio is. 4. Energy Dissipation Efficiency differs from the coefficient of friction. When the coefficient of friction is big, square column shows bigger than round one and it is bigger when the thickness of Sungetuk and Dugeup is thicker. When the coefficient of friction is small, round column shows bigger than square one.
        5,800원
        6.
        2011.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Western style timber roof trusses used as typical roof structures of buildings during a modern period have been developed with the interactions with their facade and functionality. The shapes of trusses and member sizes have been diversely changed by the purposes of architects, historical circumstances, and structural characteristics. For this reason, the change in the shapes of western style timber trusses along the times is one of important technology assets demonstrating the development of their structures during the modern period. Therefore, the purpose of this paper is to find out their structural characteristics throughout parametric analysis of which parameters were determined from the collected and classified documents on western style timber roof structure built in the modern period carefully obtained from public institutions. Results of the parametric analysis are as follows. The number of king-post trusses and modified king-post trusses built between 1920 and 1937 reaches almost half of the total number of truss types investigated. The mean values of their spans, distances, tributary areas, and height are respectively, 10.5m, 2.4m, 24.37㎡ and 3.24m. The cross-section areas of trusses tend to reduce since the city construction law was enacted in 1920. Also, this study found that western architects usually used larger structural members than eastern architects and usages and finishing materials of roof trusses are not always considered as one of the important design parameters.
        5,500원
        7.
        2013.10 서비스 종료(열람 제한)
        Woods are used as a main material for the domestic Traditional Buildings and most Traditional Wood Structures should be conserved as Traditional Assets. To be conserved, structural performance should be evaluated. So traits of the materials are to be studied. Therefore characteristics of structural deterioration of Traditional Wood Structures are to be analysed on this study.
        8.
        2012.03 KCI 등재 서비스 종료(열람 제한)
        전통 목구조는 기둥-보-도리로 가구를 구성하며, 보 장부의 파괴는 전통 목구조의 붕괴로 이어질 수 있다. 장부의 구조성능을 평가하기 위해 장부 두께에 따른 내력과 강성을 평가하고, 상부 구조체를 해체하여야 가능한 기존 보강방안을 보완하여 상부 구조체를 해체하지 않고 보강하는 방안을 제안한다. 효과적인 보강방안을 제안하기 위해 철물 개수 및 간격, 모양 및 삽입깊이를 요인으로 실험을 행하여 비보강 실험체와 내력, 강성을 비교한다. 장부의 전단실험을 통하여 다음과 같은 결론을 도출한다. 장부의 내력과 초기전단강성은 장부 두께가 두꺼워질수록 증가하지만, 장부 두께를 크게 하면 기둥의 사개부분이 약해져 구조적 안전성에 영향을 미친다. 장부의 내력 전단응력 전단강성을 효과적으로 향상시키기 위해서는 철물 3개를 장부의 중앙부에 배치하여 보강하여야 한다. 이를 토대로 기둥-보-도리 등의 접합부에 대한 연구도 진행되어야 할 것이다.
        9.
        2011.07 KCI 등재 서비스 종료(열람 제한)
        최근 생태․친환경 건축이 화두로 등장하면서 친환경 건축재료인 점토벽돌과 공기의 흐름과 수분의 이동이 가능한 석회모르타르의 사용이 증가하고 있다. 하지만 국내 연구는 콘크리트벽돌과 시멘트모르타르에 집중되고 있어 점토벽돌 및 석회모르타르에 대한 연구가 거의 없는 실정이며, 조적조의 국내 기준 또한 국내에서 사용되는 재료와 다른 물리적 값을 사용하고 있는 국외기준을 바탕으로 제정되어 국내 실정을 적절히 반영하지 못하고 있다. 따라서 본 연구는 프리즘압축강도, 부착강도, 전단 및 사인장강도 실험을 통해 점토벽돌과 석회모르타르를 사용한 조적구조의 물리적 특성을 파악하고자 한다. 또한, 콘크리트벽돌과 시멘트모르타르를 사용한 조적구조와의 물리적 특성을 비교분석하여 국내 조적기준을 개정하기 위한 근거를 제시하고자 한다. 점토벽돌과 석회모르타르를 적용한 조적구조는 콘크리트벽돌과 시멘트모르타르를 사용한 조적구조와는 다른 양상을 보이므로 점토벽돌과 석회모르타르를 적용한 조적구조의 프리즘압축강도와 탄성계수에 대한 추정식을 제안한다.
        10.
        2009.09 KCI 등재 서비스 종료(열람 제한)
        50년 이상 경과된 조적조 건축물은 석회모르타르로 시공되었으나 보수공사 시 시멘트모르타르를 사용하여 기존 재료와의 상이함으로 인한 문제가 다수 발생하였다. 또한, 조적조 건축물의 보수공사 시 참고할 수 있는 석회모르타르에 대한 객관화된 자료의 부족과 상세기준이 없으며, 미숙련 조적공의 시공으로 인하여 건축물의 객관적인 구조성능을 평가하기가 어렵다. 조적조 건축물의 원형을 보존하기 위해서는 해당 건물의 재료와 기법에 대한 기술사적 연구가 중요하다. 그러므로 본 연구는 석회모르타르의 배합비, 배합재료, 양생기간 및 조건 등에 따른 압축강도 실험을 행하고, 이를 토대로 시멘트모르타르와 석회모르타르를 비교분석하여 석회모르타르의 구조적 특성을 정리한다.