This study evaluated field application of low heat concrete using hydration heat analysis. The results of hydration heat analysis show that low heat concrete make sure of target thermal cracking index. Therefore, low heat concrete is suitable for field application.
The purpose of this study is to evaluate the effect of improvement on the impact resistance and strength properties of cement composites by surface modification of aramid fiber. For aramid fiber reinforced cement composites, therefore, dispersion capability and the bonding efficiency between the fibers and the cement composite material need to be improved. It is possible by modifying surface properties to hydrophobic, it is considered that oiling agent ratio of 1.2 % and improvement of performance is in need to be investigated. In this study, short aramid fibers were mixed by different fiber length and oiling agent ratio. And improvement of strength properties and impact resistance performance of hybrid cement composites were evaluated under the influence of steel fiber. As a result, strength properties of aramid fiber reinforced cement composites are different by mixing ratio of fiber, oiling agent ratio and length of fiber. In case of cement composites which have same volume fraction and fiber length, tensile strength and flexural strength were improved with increase of the emulsions throughput of the fiber surface. The results of evaluation on the static strength properties had effects on impact resistance performance by high-velocity impact. And it was observed that the scabbing of rear was suppressed with increase of the oiling agent ratio.
Girder type and slab type modular bridges require using UHSC(Ultra High Strength Concrete) and high performance mortar to connect each girder and slab modules at joint parts. This study presents the results of mock-up tests on the properties of UHSC and high performance mortar for modular bridge
Girder type modular bridge requires using ductile fiber reinforced concrete slab(link slab) structure to connect each girder modules at interior support points. This study presents the results of experimental evaluation on the properties and fracture energy of ductile fiber reinforced concrete for jointless modular bridge.
It was evaluated penetration depth and spalling resist thickness by compressive strength. As a result, it was found that the more compressive strength is increased, the penetration depth is suppressed. And the result of this study are similar to modified NDRC formula and US ACE formula.
본 연구에서는 분산제 코팅을 통해 성능 개선된(EP) 나일론 섬유를 혼입한 자기충전 콘크리트의 가능성을 알아보고자 하였으며, 이를 위한 실험 방법으로 나일론 섬유 길이와 다른 유기계 섬유(폴리프로필렌, 셀룰로오스)를 혼입한 경우 그리고 광물질혼화재(고로슬래그 미분말, 플라이애쉬)의 종류를 달리 혼합한 2성분계 및 3성분계의 경우를 가지고 자기충전 콘크리트의 특성을 검토하였다. 이 실험 결과를 토대로 하여 실구조물 적용을 위한 Mock-up Test를 성능 개선된 나일론 섬유를 혼입한 자기충전콘크리트 와 일반콘크리트를 비교하여 실구조물 활용 가능성을 검토 하였다. 그 결과 굳지 않은 자기충전 콘크리트의 특성, 경화된 자기충전 콘크리트의 특성 및 내구특성을 종합해 볼 때 성능 개선된(EP) 나일론 섬유가 우수함을 알 수 있었고,성능 개선된 나일론 섬유에 따른 광물질 혼화재 사용에서는 플라이애쉬 보다 고로슬래그 미분말이 우수함을 알 수 있었다.
산간 지형이 많은 국내 여건상 물류수송 및 교통 등을 위한 터널 구조물의 활용성은 매우 높다. 최근 현장에서는 공기단축 및 원가절감을 위하여 터널 굴착과 라이닝 콘크리트의 타설을 병행하는 공법이 진행되면서 굴착에 의한 진동 등의 영향으로 콘크리트 구조물 초기 재령에서 균열 및 내구성능 저하 문제가 발생하고 있다. 본 연구에서는 터널 라이닝용 콘크리트 배합에 있어서 보강재를 강섬유와 더불어 최근 국내에서 개발된 폴리아미드 섬유를 병행 사용한 콘크리트의 역학적 특성을 실험적으로 검토하였다. 또한 유․무기 섬유보강 터널 라이닝 콘크리트 부재의 하중-변위와 하중-변형률 관계를 모형 실험으로 평가하였다. 실험 결과, 보통 콘크리트에 강섬유와 폴리아미드 섬유 보강재를 하이브리드화하여 사용한 콘크리트 부재에서 구조 성능이 증진됨을 확인할 수 있었다.