검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        3.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study is to improve the fire prevention performance using the fire venetian blind louver subjected to burning by fire flame. The investigation is based on testing 2 full scale specimens, which is 3m × 3m module, 850 × 1500mm open, and 900mm × 900mm × 175mm venetian blind louver. Two louver thickness (1.5 and 2.0mm) were adopted. The specimens were exposed to fire flame temperature levels of ISO834 at the lower surface of the fire venetian blind louver specimens with exposure duration of one hour in Korea Institute of Construction Technology (KICT). It was found from the test results that the values of distributed temperature, decreased for all specimens for protecting to fire flame by venetian blind louver. The results of tests were a good fire prevention performance between in initial to 6 mins. At 60 minutes around ISO 834 fire loading, the percentages of distributed temperature in 500mm and 800mm height ranged between 11 and 10% respectively, regardless of louver thickness. This study, therefore, will improve the fire venetian blind louver for fire protection and prevention performance.
        4.
        2010.11 KCI 등재 서비스 종료(열람 제한)
        콘크리트 믹서트럭의 덮개는 레미콘 플랜트에서 공사 현장까지의 운반 도중 굳지 않은 콘크리트의 유동성이 저하하지 않도록 사용하는데, 설문 결과 일반시민들에게 더러운 이미지를 주고 있다. 이러한 이미지로 인해 건설 산업 전체의 이미지에도 영향을 미칠 것으로 예상하여 덮개의 효용성 여부를 밝히기 위해 레미콘을 현장에 대기시켜 둔 채 유동성을 비롯한 공기량, 콘크리트 온도변화 등의 현장 실험을 실시하였다. 또한 이와 비교를 위해 동일한 조건으로 실내 실험을 병행하여 결과를 도출하였다. 실험 결과, 믹서트럭의 덮개는 슬럼프 저하에 미치는 영향이 적은 것으로 나타났다. 공기량 변화는 덮개 유무에 관계없이 60분까지는 적정한 수준으로 품질에 큰 영향을 미치지 않는 것으로 나타났다. 또한 콘크리트 압축강도는 덮개 유무에 관계없이 90분까지의 시료의 경우에 목표설계기준강도에 모두 적합한 것으로 나타났다.